# C1V1 = C2V2: the dilution formula with worked examples

> C1V1 = C2V2 with worked examples: 10× buffer to 1×, a 1:1000 antibody, serial dilutions, consistent units, and when the dilution formula does not apply.

Published 2026-11-22, updated 2026-11-22 by LabCanvas team. https://www.labcanvas.com/blog/c1v1-c2v2-dilution-formula

![A 10 mM stock tube and a 1 mL tube of 1 mM made from 100 µL of stock and 900 µL of diluent, with C₁V₁ = C₂V₂ written between them](https://www.labcanvas.com/blog/lab/c1v1-c2v2-dilution-formula.svg)

**C₁V₁ = C₂V₂** says that the amount of solute you pipette from a stock (concentration C₁ times volume V₁) is the amount in the diluted solution (concentration C₂ times final volume V₂). Solve it for the stock volume: **V₁ = C₂V₂ / C₁**, then add diluent up to V₂. For 1 mL of 1 mM from a 10 mM stock: V₁ = 1 mM × 1 mL / 10 mM = 100 µL, plus 900 µL of diluent.

Below: how to use the formula without unit mistakes, worked examples for the dilutions done every day (a 10× buffer, a salt stock, a 1:1000 antibody, a buffer made from several stocks), serial dilutions, and the cases where C₁V₁ = C₂V₂ gives the wrong answer. The [dilution calculator](https://www.labcanvas.com/tools/dilution-calculator) does each of these.

## Why it works

Amount of solute = concentration × volume, whether the amount is in moles (M × L), grams (g/L × L) or "times" of a concentrated buffer. Diluting adds solvent and nothing else, so the amount is the same before and after:

$$C_1 V_1 = C_2 V_2 \quad\Rightarrow\quad V_1 = \frac{C_2 V_2}{C_1}$$

Any one of the four values can be the unknown: the stock concentration that a given volume must have been (\(C_1 = C_2 V_2 / V_1\)), the concentration you get (\(C_2 = C_1 V_1 / V_2\)), or the final volume a given amount of stock makes (\(V_2 = C_1 V_1 / C_2\)). The **dilution factor** is \(C_1 / C_2 = V_2 / V_1\): a 1:10 dilution is 1 part stock in 10 parts final volume.

## Four steps, and keep the units the same

1. **Write down the three values you know**, with units.
2. **Put both concentrations in the same unit, and both volumes in the same unit.** The answer comes out in the volume unit you used.
3. **Solve** for the unknown.
4. **Diluent = V₂ − V₁.** V₂ is the total, not the water you add.

The commonest error is a unit left unconverted. Diluting 5 M NaCl to 150 mM, 200 mL: written as 150 × 200 / 5 the answer is 6000, which is nonsense. Convert 5 M to 5000 mM first: \(V_1 = 150 \times 200 / 5000\) = **6 mL** of 5 M stock and 194 mL of water. Molar units (mM) and mass units (mg/mL) cannot be mixed in the formula at all without the molar mass: convert one into the other with the [concentration converter](https://www.labcanvas.com/tools/concentration-converter) first. The dilution calculator refuses a pair of units that cannot be converted.

## Worked examples

| Dilution | C₁ | C₂ | V₂ | Stock V₁ | Diluent | Factor |
|---|---|---|---|---|---|---|
| A working solution | 10 mM | 1 mM | 1 mL | 100 µL | 900 µL | 1:10 |
| 10× PBS to 1× | 10× | 1× | 500 mL | 50 mL | 450 mL | 1:10 |
| 5 M NaCl to 150 mM | 5000 mM | 150 mM | 200 mL | 6 mL | 194 mL | 1:33.33 |
| Antibody 1:1000 | 1000× | 1× | 10 mL | 10 µL | 9.99 mL | 1:1000 |

**A 10× buffer to 1×.** Concentrated buffers are labelled 10×, 5× or 50×; use those numbers as the concentrations. For 500 mL of 1× PBS: \(V_1 = 1 \times 500\ \mathrm{mL} / 10\) = **50 mL** of 10× PBS made up to 500 mL with 450 mL of water. The same works for 50× TAE (20 mL per litre of 1×) and 10× TBE.

**An antibody at 1:1000.** A ratio is a dilution factor: 1:1000 means 1 part antibody in 1000 parts of final volume, so the stock is "1000×" and the working solution "1×". For 10 mL of blocking buffer: \(V_1 = 10\ \mathrm{mL} / 1000\) = **10 µL** of antibody in 9.99 mL of buffer. In the dilution calculator, enter 1000 × and 1 ×. Some older protocols write 1:10 to mean 1 part plus 10 parts (1:11 in total); most mean 1 in 10. Check which yours means.

**When V₁ is too small to pipette.** At 1:10,000 in 5 mL, V₁ is 500 nL (0.5 µL), below what most pipettes deliver accurately. Dilute in two steps: first 1:100 (for example 2 µL of antibody in 198 µL of buffer), then 1:100 again, 50 µL of that intermediate in 4.95 mL of buffer. The total factor is 100 × 100 = 10,000.

## A buffer from several stocks

Each solute gets its own C₁V₁ = C₂V₂, all with the same final volume. For 100 mL of 50 mM Tris-HCl, 150 mM NaCl, 1 mM EDTA from 1 M Tris-HCl, 5 M NaCl and 0.5 M EDTA:

| Component | Stock | Final | Stock volume |
|---|---|---|---|
| Tris-HCl | 1 M (1000 mM) | 50 mM | 5 mL |
| NaCl | 5 M (5000 mM) | 150 mM | 3 mL |
| EDTA | 0.5 M (500 mM) | 1 mM | 200 µL |

Then add water to 100 mL: about 91.8 mL, but make up to the mark rather than adding a calculated volume of water, because volumes do not always add up exactly. Each stock is diluted by the others as well as by the water, which is why every line uses the same V₂ of 100 mL.

## Serial dilutions

A serial dilution repeats the same dilution tube after tube: each tube is diluted by a factor f from the one before, so tube k holds \(C_0 / f^k\), and the total dilution after n steps is \(f^n\). Each step is a C₁V₁ = C₂V₂ with C₂ = C₁ / f.

The dilution calculator's serial plan keeps the same final volume V in every tube: put V of diluent in each tube, then move \(V / (f - 1)\) along the series, mixing each time. For six 1:10 steps from 1 mM with 1 mL per tube, that is 1 mL of diluent in each tube and a transfer of **111.1 µL**:

| Tube | Concentration | Dilution |
|---|---|---|
| Stock | 1 mM | 1 |
| 1 | 100 µM | 1:10 |
| 2 | 10 µM | 1:100 |
| 3 | 1 µM | 1:1,000 |
| 4 | 100 nM | 1:10,000 |
| 5 | 10 nM | 1:100,000 |
| 6 | 1 nM | 1:1,000,000 |

Many protocols instead add 100 µL to 900 µL in each tube: the factor is the same 1:10, and each tube is left with 900 µL after its transfer. For a 2-fold series, such as a BSA standard curve, the transfer equals the volume already in the tube: with 250 µL per tube, 250 µL into 250 µL. Pipetting errors carry on down a serial dilution (Ben-David and Davidson 2014), so use a fresh tip and mix well at every step.

## Mixing two solutions of the same solute

C₁V₁ = C₂V₂ describes adding pure solvent. When you mix two solutions that both contain the solute, add up the amounts:

$$C_\text{mix} = \frac{C_1 V_1 + C_2 V_2}{V_1 + V_2}$$

20 mL of 1 M NaCl plus 30 mL of 0.5 M NaCl gives \((1 \times 20 + 0.5 \times 30) / 50\) = 0.7 M, provided the volumes add up, which is close enough for dilute aqueous solutions.

## When C₁V₁ = C₂V₂ does not apply

- **Concentrations per mass, not per volume.** Molality is moles per kilogram of solvent (IUPAC Green Book), and % w/w is grams per 100 g of solution. Diluting them is a balance of masses, not volumes: for molality \(b_1 m_1 = b_2 m_2\) with \(m\) the mass of solvent, so halving a 2 mol/kg solution means doubling the mass of solvent it contains; for % w/w, \(w_1 m_1 = w_2 m_2\) with \(m\) the mass of solution. Convert to molarity first (the [concentration converter](https://www.labcanvas.com/tools/concentration-converter) does it with the density), or work by mass.
- **Volumes that do not add up.** Ethanol and water contract when mixed, and concentrated solutions such as strong acids do not mix ideally with water either (diluting a concentrated acid also releases a lot of heat: always add acid to water). For 70 % ethanol, measure 70 mL of ethanol and make up to 100 mL with water, rather than adding exactly 30 mL. The formula still gives the volume of stock; make up to the final volume instead of adding a calculated volume of diluent.
- **Two solutions of the same solute.** Use the mixing equation above.
- **Reactions, precipitation or a change of pH.** If anything reacts, precipitates or comes out of solution when diluted, the amount in solution is no longer conserved. The pH of a buffer can also shift when it is diluted, because the ionic strength changes; check the pH of the working solution if it matters.

## Common dilution mistakes

- **Using V₂ as the volume of diluent.** For 1 mL of a 1:10 dilution, 100 µL of stock goes into 900 µL, not into 1 mL.
- **Leaving M and mM, or mL and µL, unconverted.** Each slip is a factor of 1000.
- **Pipetting volumes too small to be accurate.** Make an intermediate dilution instead.
- **Not mixing between serial steps**, so every later tube is wrong.
- **A final concentration higher than the stock.** C₂ must be lower than C₁; if the arithmetic says otherwise, a unit is wrong.

## Do it with the calculator

In the [dilution calculator](https://www.labcanvas.com/tools/dilution-calculator), choose what to solve for (V₁, C₁, C₂ or V₂), type the three values you know with their units (10 mM, 1 mL, 1000 ×, 70 %) and copy the instruction it writes, for example "Add 100 µL of the 10 mM stock to 900 µL of diluent (total 1 mL)". Switch to **Serial dilution** for a tube-by-tube table you can download as CSV. To make the stock in the first place, see [how to make a 1 M NaCl solution](https://www.labcanvas.com/blog/how-to-make-1m-nacl-solution) and the [molarity calculator](https://www.labcanvas.com/tools/molarity-calculator).

## References

- Cohen ER, Cvitaš T, Frey JG, et al. (2007). *Quantities, Units and Symbols in Physical Chemistry* (IUPAC Green Book), 3rd edition. RSC Publishing. [doi:10.1039/9781847557889](https://doi.org/10.1039/9781847557889)
- Ben-David A, Davidson CE (2014). Estimation method for serial dilution experiments. *Journal of Microbiological Methods* 107, 214–221. [doi:10.1016/j.mimet.2014.08.023](https://doi.org/10.1016/j.mimet.2014.08.023)

## Frequently asked questions

### What does C1V1 = C2V2 mean?

The amount of solute you take from the stock (its concentration C₁ times the volume V₁) is the amount in the diluted solution (C₂ times the final volume V₂). Adding solvent changes the volume, not the amount of solute.

### How do I solve C1V1 = C2V2 for V1?

Rearrange to V₁ = C₂ × V₂ ÷ C₁. For 1 mL of 1 mM from a 10 mM stock, V₁ = 1 mM × 1 mL ÷ 10 mM = 100 µL; add 900 µL of diluent to reach 1 mL.

### Is V2 the volume of water to add?

No. V₂ is the final total volume. The diluent is V₂ − V₁: for 1 mL of a 1:10 dilution, 100 µL of stock plus 900 µL of diluent, not plus 1 mL.

### How do I dilute an antibody 1:1000?

Take 1 part of antibody per 1000 parts of final volume. For 10 mL, 10 µL of antibody plus 9.99 mL of buffer. In the dilution calculator, enter the stock as 1000 × and the final as 1 ×.

### How do I make 1× buffer from a 10× stock?

Treat 10× and 1× as concentrations: V₁ = 1 × 500 mL ÷ 10 = 50 mL of 10× stock, made up to 500 mL with 450 mL of water.

### Do the units have to match in C1V1 = C2V2?

Both concentrations must be in the same unit and both volumes in the same unit. Diluting 5 M NaCl to 150 mM, write 5 M as 5000 mM: V₁ = 150 × 200 mL ÷ 5000 = 6 mL. Molar and mass units (mM and mg/mL) cannot be mixed without the molar mass.

### When does C1V1 = C2V2 not work?

When the concentration is not per volume of solution (molality, % w/w), when volumes do not add up (ethanol and water, concentrated acids), when you mix two solutions of the same solute at different concentrations, or when something reacts or precipitates on mixing.

## Related links

- [Dilution calculator](https://www.labcanvas.com/tools/dilution-calculator): C₁V₁ = C₂V₂ for any missing value, and serial dilution tables
- [Molarity calculator](https://www.labcanvas.com/tools/molarity-calculator): Make the stock first: grams to weigh for any molarity
- [Concentration converter](https://www.labcanvas.com/tools/concentration-converter): Convert mM, mg/mL, % and ppm before you dilute
- [How to make a 1 M NaCl solution (and any molar solution)](https://www.labcanvas.com/blog/how-to-make-1m-nacl-solution): Weighing, dissolving and making up to volume
- [ΔΔCt method step by step](https://www.labcanvas.com/blog/delta-delta-ct-method): Where a dilution series becomes a qPCR standard curve
- [All lab calculators](https://www.labcanvas.com/tools/lab-calculators): Solutions, molecular biology, cell culture and assays