# Electrochemical biosensors: from a drop on an electrode to a number

> A glucose test strip followed from sample to signal: a drop on a screen-printed electrode, glucose oxidase turning glucose into gluconolactone, hydrogen peroxide oxidised at the electrode near +0.6 V, and a calibration that turns current into a concentration. Below, the other ways to get the electrons out: a redox mediator, direct electron transfer, and affinity sensors in which binding moves a redox tag (E-DNA at 10 pM, an aptamer for thrombin in serum).

- Page: https://www.labcanvas.com/templates/graphical-abstracts/electrochemical-biosensors-drop-electrode-number
- Open in the LabCanvas editor (LabCanvas account): https://www.labcanvas.com/editor.html?template=electrochemical-biosensor-from-electrode-to-signal
- Updated: 2026-10-14
- Category: Graphical abstracts
- Method: Graphical abstract
- Starting materials: A drop of sample on a screen-printed electrode carrying a bioreceptor
- Product: A current, calibrated into a concentration
- Key result: H₂O₂ oxidised near +0.6 V at platinum (Wang 2008; Heller & Feldman 2008); E-DNA to 10 pM target (Fan et al. 2003); thrombin in blood serum (Xiao et al. 2005); calibration illustrative
- Figure: 1920 × 1080 px, 79 editable layers (3 generated objects with settings)

## Steps

1. **1 · Sample**: A drop lands on a disposable screen-printed strip: a carbon working electrode with the enzyme, a counter electrode and an Ag/AgCl reference (Metters, Kadara & Banks 2011)
2. **2 · Recognise**: Glucose oxidase oxidises glucose to gluconolactone; its FAD takes the electrons and O₂ turns into H₂O₂ (first generation; Clark & Lyons 1962)
3. **3 · Transduce**: H₂O₂ is oxidised at the electrode near +0.6 V: two electrons per glucose (Wang 2008; Heller & Feldman 2008)
4. **4 · Read out**: A calibration turns the current into a concentration; 1 mmol/L glucose = 18.016 mg/dL
5. **Mediator and direct transfer**: A mediator (ferrocene, ferricyanide, an osmium redox polymer) carries the electrons instead of O₂ (second generation), or they pass straight from the enzyme (third)
6. **Affinity sensors**: Binding moves a redox tag: E-DNA detects 10 pM DNA (Fan et al. 2003); a methylene-blue aptamer reads thrombin in serum (Xiao et al. 2005)

## Uses

- Graphical abstracts on electrochemical biosensors and glucose sensing
- Teaching how an enzyme electrode works
- Talks on point-of-care diagnostics

## References

1. Thévenot, Toth, Durst & Wilson, “Electrochemical biosensors: recommended definitions and classification”, Biosens. Bioelectron. 2001. https://doi.org/10.1016/S0956-5663(01)00115-4 (review)
2. Metters, Kadara & Banks, “New directions in screen printed electroanalytical sensors: an overview of recent developments”, Analyst 2011. https://doi.org/10.1039/c0an00894j (review)
3. Clark & Lyons, “Electrode systems for continuous monitoring in cardiovascular surgery”, Ann. N. Y. Acad. Sci. 1962. https://doi.org/10.1111/j.1749-6632.1962.tb13623.x (primary)
4. Wang, “Electrochemical glucose biosensors”, Chem. Rev. 2008. https://doi.org/10.1021/cr068123a (review)
5. Heller & Feldman, “Electrochemical glucose sensors and their applications in diabetes management”, Chem. Rev. 2008. https://doi.org/10.1021/cr068069y (review)
6. Fan, Plaxco & Heeger, “Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA”, Proc. Natl. Acad. Sci. USA 2003. https://doi.org/10.1073/pnas.1633515100 (primary)
7. Xiao, Lubin, Heeger & Plaxco, “Label-free electronic detection of thrombin in blood serum by using an aptamer-based sensor”, Angew. Chem. Int. Ed. 2005. https://doi.org/10.1002/anie.200500989 (primary)

Credit: Drawn by LabCanvas after Thévenot et al., Biosens. Bioelectron. 2001 (doi:10.1016/S0956-5663(01)00115-4); Metters, Kadara & Banks, Analyst 2011 (doi:10.1039/c0an00894j); Clark & Lyons, Ann. N. Y. Acad. Sci. 1962 (doi:10.1111/j.1749-6632.1962.tb13623.x); Wang, Chem. Rev. 2008 (doi:10.1021/cr068123a); Heller & Feldman, Chem. Rev. 2008 (doi:10.1021/cr068069y); Fan, Plaxco & Heeger, PNAS 2003 (doi:10.1073/pnas.1633515100); Xiao et al., Angew. Chem. 2005 (doi:10.1002/anie.200500989). Calibration illustrative; strip and layers schematic.

## Questions

**What does the “Electrochemical biosensors: from a drop on an electrode to a number” template show?** A glucose test strip followed from sample to signal: a drop on a screen-printed electrode, glucose oxidase turning glucose into gluconolactone, hydrogen peroxide oxidised at the electrode near +0.6 V, and a calibration that turns current into a concentration. Below, the other ways to get the electrons out: a redox mediator, direct electron transfer, and affinity sensors in which binding moves a redox tag (E-DNA at 10 pM, an aptamer for thrombin in serum).

**What are the steps shown in “Electrochemical biosensors: from a drop on an electrode to a number”?** 1. 1 · Sample: A drop lands on a disposable screen-printed strip: a carbon working electrode with the enzyme, a counter electrode and an Ag/AgCl reference (Metters, Kadara & Banks 2011). 2. 2 · Recognise: Glucose oxidase oxidises glucose to gluconolactone; its FAD takes the electrons and O₂ turns into H₂O₂ (first generation; Clark & Lyons 1962). 3. 3 · Transduce: H₂O₂ is oxidised at the electrode near +0.6 V: two electrons per glucose (Wang 2008; Heller & Feldman 2008). 4. 4 · Read out: A calibration turns the current into a concentration; 1 mmol/L glucose = 18.016 mg/dL. 5. Mediator and direct transfer: A mediator (ferrocene, ferricyanide, an osmium redox polymer) carries the electrons instead of O₂ (second generation), or they pass straight from the enzyme (third). 6. Affinity sensors: Binding moves a redox tag: E-DNA detects 10 pM DNA (Fan et al. 2003); a methylene-blue aptamer reads thrombin in serum (Xiao et al. 2005).

**What are the starting materials and the product?** Starting materials: A drop of sample on a screen-printed electrode carrying a bioreceptor. Product: A current, calibrated into a concentration.

**Which papers is “Electrochemical biosensors: from a drop on an electrode to a number” based on?** Thévenot, Toth, Durst & Wilson, “Electrochemical biosensors: recommended definitions and classification”, Biosens. Bioelectron. 2001 (doi:10.1016/S0956-5663(01)00115-4); Metters, Kadara & Banks, “New directions in screen printed electroanalytical sensors: an overview of recent developments”, Analyst 2011 (doi:10.1039/c0an00894j); Clark & Lyons, “Electrode systems for continuous monitoring in cardiovascular surgery”, Ann. N. Y. Acad. Sci. 1962 (doi:10.1111/j.1749-6632.1962.tb13623.x); Wang, “Electrochemical glucose biosensors”, Chem. Rev. 2008 (doi:10.1021/cr068123a); Heller & Feldman, “Electrochemical glucose sensors and their applications in diabetes management”, Chem. Rev. 2008 (doi:10.1021/cr068069y); Fan, Plaxco & Heeger, “Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA”, Proc. Natl. Acad. Sci. USA 2003 (doi:10.1073/pnas.1633515100); Xiao, Lubin, Heeger & Plaxco, “Label-free electronic detection of thrombin in blood serum by using an aptamer-based sensor”, Angew. Chem. Int. Ed. 2005 (doi:10.1002/anie.200500989).

**Can I edit the “Electrochemical biosensors: from a drop on an electrode to a number” template?** Yes. Open it in the LabCanvas editor: all 79 layers are editable, including 3 generated objects (structures, plots, equipment) with their own settings. Change the text, colours and layout, then export PNG, TIFF or PDF at the width and DPI the journal asks for.

**Do I need an account to use this template?** Not to view it here. To open and edit it, sign in to LabCanvas or create a free account (the free plan keeps up to 3 designs). Downloading the figure is part of LabCanvas Pro (US$19 a month or US$199 a year).