# Flow and microfluidic synthesis: reproducible nanoparticles, scaled out and self-optimising

> Continuous-flow nanoparticle synthesis as time turned into distance: precursors meet in a mixer, grow in a heated coil, are quenched in a cooled one and measured in line, so the growth time is how far along the tube a slug has travelled. Segmented flow gives every slug the same history; copying the reactor side by side gave 145 g of quantum dots a day with identical spectra in every channel; and a closed loop with machine learning found eleven quantum-dot recipes in 30 h. Lipid nanoparticles show the same control: 20 nm and up, polydispersity 0.02.

- Page: https://www.labcanvas.com/templates/graphical-abstracts/flow-microfluidic-synthesis-reproducible-nanoparticles-scaled-out-self-o
- Open in the LabCanvas editor (LabCanvas account): https://www.labcanvas.com/editor.html?template=continuous-flow-microfluidic-nanoparticle-synthesis-scale-up
- Updated: 2026-10-14
- Category: Graphical abstracts
- Method: Graphical abstract
- Starting materials: Precursor solutions pumped continuously (cadmium and selenium precursors for CdSe; lipids in ethanol and siRNA in buffer for LNPs), with an inert gas or immiscible carrier to segment the flow
- Product: Nanocrystals and lipid nanoparticles made continuously, with the same size and spectra over hours
- Key result: 145 g/day CdTe, 54.4 g in 9 h (Nightingale et al. 2013); 11 compositions in 30 h, < 210 mL, within 1 meV of target (Epps et al. 2020); LNP PDI 0.02 (Belliveau et al. 2012)
- Figure: 1920 × 1080 px, 122 editable layers (1 generated objects with settings)

## Steps

1. **Time becomes distance**: Mix, grow in a heated zone, quench in a cooled zone: a gas–liquid segmented microreactor made monodisperse CdSe with narrow residence-time distributions (Yen et al. 2005)
2. **Same history for every slug**: Segmented flow removes velocity dispersion, a significant cause of polydispersity, and reduces fouling (Nightingale & deMello 2013)
3. **Scale out**: A multichannel droplet reactor gave identical spectra in every channel and over time: 54.4 g of CdTe in 9 h, 145 g per day (Nightingale et al. 2013)
4. **Close the loop**: Online spectra map conditions quickly (Lignos et al. 2016); machine learning with autonomous flow made eleven tailored compositions in 30 h from < 210 mL (Epps et al. 2020)
5. **Beyond quantum dots**: Millisecond microfluidic mixing makes lipid nanoparticles from 20 nm with PDI as low as 0.02 (Belliveau et al. 2012); herringbone floors mix laminar streams (Stroock et al. 2002)

## Uses

- Graphical abstracts on flow and microfluidic nanomaterial synthesis
- Talks on reproducible scale-up and self-driving labs
- Teaching residence time and segmented flow

## References

1. Yen, Günther, Schmidt, Jensen & Bawendi, “A microfabricated gas–liquid segmented flow reactor for high-temperature synthesis: the case of CdSe quantum dots”, Angew. Chem. Int. Ed. 2005. https://doi.org/10.1002/anie.200500792 (primary)
2. Nightingale & deMello, “Segmented flow reactors for nanocrystal synthesis”, Adv. Mater. 2013. https://doi.org/10.1002/adma.201203252 (review)
3. Nightingale et al., “Large-scale synthesis of nanocrystals in a multichannel droplet reactor”, J. Mater. Chem. A 2013. https://doi.org/10.1039/c3ta10458c (primary)
4. Lignos et al., “Synthesis of cesium lead halide perovskite nanocrystals in a droplet-based microfluidic platform: fast parametric space mapping”, Nano Lett. 2016. https://doi.org/10.1021/acs.nanolett.5b04981 (primary)
5. Epps et al., “Artificial Chemist: an autonomous quantum dot synthesis bot”, Adv. Mater. 2020. https://doi.org/10.1002/adma.202001626 (primary)
6. Belliveau et al., “Microfluidic synthesis of highly potent limit-size lipid nanoparticles for in vivo delivery of siRNA”, Mol. Ther. Nucleic Acids 2012. https://doi.org/10.1038/mtna.2012.28 (primary)
7. Stroock et al., “Chaotic mixer for microchannels”, Science 2002. https://doi.org/10.1126/science.1066238 (primary)
8. Marre & Jensen, “Synthesis of micro and nanostructures in microfluidic systems”, Chem. Soc. Rev. 2010. https://doi.org/10.1039/b821324k (review)

Credit: Drawn by LabCanvas after Yen et al., Angew. Chem. Int. Ed. 2005 (doi:10.1002/anie.200500792); Nightingale & deMello, Adv. Mater. 2013 (doi:10.1002/adma.201203252); Nightingale et al., J. Mater. Chem. A 2013 (doi:10.1039/c3ta10458c); Lignos et al., Nano Lett. 2016 (doi:10.1021/acs.nanolett.5b04981); Epps et al., Adv. Mater. 2020 (doi:10.1002/adma.202001626); Belliveau et al., Mol. Ther. Nucleic Acids 2012 (doi:10.1038/mtna.2012.28); Stroock et al., Science 2002 (doi:10.1126/science.1066238); Marre & Jensen, Chem. Soc. Rev. 2010 (doi:10.1039/b821324k). Flow profiles schematic.

## Questions

**What does the “Flow and microfluidic synthesis: reproducible nanoparticles, scaled out and self-optimising” template show?** Continuous-flow nanoparticle synthesis as time turned into distance: precursors meet in a mixer, grow in a heated coil, are quenched in a cooled one and measured in line, so the growth time is how far along the tube a slug has travelled. Segmented flow gives every slug the same history; copying the reactor side by side gave 145 g of quantum dots a day with identical spectra in every channel; and a closed loop with machine learning found eleven quantum-dot recipes in 30 h. Lipid nanoparticles show the same control: 20 nm and up, polydispersity 0.02.

**What are the steps shown in “Flow and microfluidic synthesis: reproducible nanoparticles, scaled out and self-optimising”?** 1. Time becomes distance: Mix, grow in a heated zone, quench in a cooled zone: a gas–liquid segmented microreactor made monodisperse CdSe with narrow residence-time distributions (Yen et al. 2005). 2. Same history for every slug: Segmented flow removes velocity dispersion, a significant cause of polydispersity, and reduces fouling (Nightingale & deMello 2013). 3. Scale out: A multichannel droplet reactor gave identical spectra in every channel and over time: 54.4 g of CdTe in 9 h, 145 g per day (Nightingale et al. 2013). 4. Close the loop: Online spectra map conditions quickly (Lignos et al. 2016); machine learning with autonomous flow made eleven tailored compositions in 30 h from < 210 mL (Epps et al. 2020). 5. Beyond quantum dots: Millisecond microfluidic mixing makes lipid nanoparticles from 20 nm with PDI as low as 0.02 (Belliveau et al. 2012); herringbone floors mix laminar streams (Stroock et al. 2002).

**What are the starting materials and the product?** Starting materials: Precursor solutions pumped continuously (cadmium and selenium precursors for CdSe; lipids in ethanol and siRNA in buffer for LNPs), with an inert gas or immiscible carrier to segment the flow. Product: Nanocrystals and lipid nanoparticles made continuously, with the same size and spectra over hours.

**Which papers is “Flow and microfluidic synthesis: reproducible nanoparticles, scaled out and self-optimising” based on?** Yen, Günther, Schmidt, Jensen & Bawendi, “A microfabricated gas–liquid segmented flow reactor for high-temperature synthesis: the case of CdSe quantum dots”, Angew. Chem. Int. Ed. 2005 (doi:10.1002/anie.200500792); Nightingale & deMello, “Segmented flow reactors for nanocrystal synthesis”, Adv. Mater. 2013 (doi:10.1002/adma.201203252); Nightingale et al., “Large-scale synthesis of nanocrystals in a multichannel droplet reactor”, J. Mater. Chem. A 2013 (doi:10.1039/c3ta10458c); Lignos et al., “Synthesis of cesium lead halide perovskite nanocrystals in a droplet-based microfluidic platform: fast parametric space mapping”, Nano Lett. 2016 (doi:10.1021/acs.nanolett.5b04981); Epps et al., “Artificial Chemist: an autonomous quantum dot synthesis bot”, Adv. Mater. 2020 (doi:10.1002/adma.202001626); Belliveau et al., “Microfluidic synthesis of highly potent limit-size lipid nanoparticles for in vivo delivery of siRNA”, Mol. Ther. Nucleic Acids 2012 (doi:10.1038/mtna.2012.28); Stroock et al., “Chaotic mixer for microchannels”, Science 2002 (doi:10.1126/science.1066238); Marre & Jensen, “Synthesis of micro and nanostructures in microfluidic systems”, Chem. Soc. Rev. 2010 (doi:10.1039/b821324k).

**Can I edit the “Flow and microfluidic synthesis: reproducible nanoparticles, scaled out and self-optimising” template?** Yes. Open it in the LabCanvas editor: all 122 layers are editable, including 1 generated objects (structures, plots, equipment) with their own settings. Change the text, colours and layout, then export PNG, TIFF or PDF at the width and DPI the journal asks for.

**Do I need an account to use this template?** Not to view it here. To open and edit it, sign in to LabCanvas or create a free account (the free plan keeps up to 3 designs). Downloading the figure is part of LabCanvas Pro (US$19 a month or US$199 a year).