# Free scientific tools

> 75 free tools for scientific figures, lab calculations and data analysis, in the browser with no account.

URL: https://www.labcanvas.com/tools

## Free apps

- [Whiteboard](https://www.labcanvas.com/whiteboard) ([Markdown](https://www.labcanvas.com/whiteboard.md)): A free online whiteboard for scientists and researchers: brainstorm, plan experiments and map the literature on an infinite canvas, with no account.

## Figures

- [LaTeX equation to PNG](https://www.labcanvas.com/tools/latex) ([Markdown](https://www.labcanvas.com/tools/latex.md)): Type a LaTeX equation, pick a colour and size, and download it as a transparent PNG at 150–1200 dpi (with its DPI recorded), or open it in the LabCanvas editor as an editable vector equation. The equation is typeset by MathJax in your browser, supports AMS environments and chemical equations with \ce{…}, and works in PowerPoint, Google Slides, Word, Keynote and figure editors.
- [Colorblind-safe scientific color palettes](https://www.labcanvas.com/tools/palettes) ([Markdown](https://www.labcanvas.com/tools/palettes.md)): Pick a published colour palette for your scientific figures (Okabe–Ito, Paul Tol, viridis, cividis, ColorBrewer and journal-style sets), see it on a chart as people with protanopia, deuteranopia or tritanopia would, and copy the colours as HEX codes or ready-to-paste Python (matplotlib), R (ggplot2), CSS or JSON.
- [Colour-blindness checker for scientific figures](https://www.labcanvas.com/tools/scientific-figure-color-blindness-checker) ([Markdown](https://www.labcanvas.com/tools/scientific-figure-color-blindness-checker.md)): Upload a figure, chart or micrograph to see how it looks with protanopia, deuteranopia, tritanopia and monochrome vision, side by side. The checker also finds the main colours in the image and lists pairs that become hard to tell apart, so you know what to fix before submission. The image never leaves your browser.
- [Multi-panel figure maker for journals](https://www.labcanvas.com/tools/figure-panel-maker) ([Markdown](https://www.labcanvas.com/tools/figure-panel-maker.md)): Add your images, choose a layout (2 × 2, 1 × 3, five panels as 2 + 3, a large panel with two small ones and more), set the journal column width and the panel letters, and export the multi-panel figure as a PNG at 300, 600 or 1200 dpi that records its resolution. Everything happens in your browser.
- [Scientific figure legend generator](https://www.labcanvas.com/tools/scientific-figure-legend-generator) ([Markdown](https://www.labcanvas.com/tools/scientific-figure-legend-generator.md)): A figure legend gives the main finding as its title, one sentence per panel, how the data are shown (for example mean ± s.e.m.), n, the statistical test, the significance thresholds and the scale bars. Fill in those parts and copy a complete legend in Nature, Cell Press or a generic style, ready for your manuscript; nothing is invented.
- [Molecular orbital diagram generator](https://www.labcanvas.com/tools/molecular-orbital-diagram-generator) ([Markdown](https://www.labcanvas.com/tools/molecular-orbital-diagram-generator.md)): Pick a diatomic molecule or ion and the generator draws its molecular orbital (MO) diagram; for O₂, for example, it shows bond order 2 with two unpaired electrons in the π* orbitals, which is why oxygen is paramagnetic. The diagram has the atomic orbitals of each atom at the sides, the bonding and antibonding molecular orbitals in the middle in the correct order, and the electrons filled by the aufbau principle, the Pauli principle and Hund’s rule. It gives the MO electron configuration, the bond order, (bonding − antibonding electrons) / 2, whether the species is paramagnetic or diamagnetic, and whether it is expected to exist. Download the diagram as a PNG, or edit it in the LabCanvas editor.
- [CONSORT flow diagram generator](https://www.labcanvas.com/tools/consort-flow-diagram-generator) ([Markdown](https://www.labcanvas.com/tools/consort-flow-diagram-generator.md)): Type the numbers from your randomised trial (assessed for eligibility, excluded with reasons, randomised, then for each arm allocated, received the intervention, discontinued, lost to follow-up and analysed) and the generator draws the CONSORT flow diagram with the four stages (enrolment, allocation, follow-up, analysis) as you type. It checks that the counts add up, follows the box wording of the CONSORT 2025 template (or CONSORT 2010), handles two or three arms, and exports a 300 or 600 dpi PNG and plain text, or opens the diagram in the LabCanvas editor as editable vectors.
- [PRISMA 2020 flow diagram generator](https://www.labcanvas.com/tools/prisma-flow-diagram-generator) ([Markdown](https://www.labcanvas.com/tools/prisma-flow-diagram-generator.md)): Enter the counts from your systematic review search (records from each database and register, duplicates and other records removed, records screened and excluded, reports sought, not retrieved, assessed and excluded with reasons, and the studies and reports included) and the generator draws the PRISMA 2020 flow diagram as you type. Switch on the “other methods” column for websites, organisations and citation searching. It checks that every step adds up, fills derived counts for you, and exports a 300 or 600 dpi PNG and plain text, or opens the diagram in the LabCanvas editor as editable vectors.
- [Journal figure size and DPI checker and resizer](https://www.labcanvas.com/tools/journal-figure-size) ([Markdown](https://www.labcanvas.com/tools/journal-figure-size.md)): A journal figure needs width in inches × dpi pixels across: a Nature single-column figure is 89 mm wide, 89 ÷ 25.4 = 3.504 inches, so at 300 dpi it needs 1051 pixels. Choose a journal, a column width and the kind of image (photo, combination or line art), open your PNG, JPEG or TIFF, and the tool shows its pixel size, the DPI the file records, the DPI it would have at that width and whether it has enough pixels. It then resamples the image to exactly that width, or only rewrites the DPI, and saves a PNG with the DPI recorded so it is placed at the right size.
- [Add a scale bar to a microscope image](https://www.labcanvas.com/tools/scale-bar-adder) ([Markdown](https://www.labcanvas.com/tools/scale-bar-adder.md)): A scale bar is its length divided by the pixel size: at 0.325 µm per pixel a 100 µm bar is 100 ÷ 0.325 = 307.7 pixels long. Open a micrograph (PNG, JPEG or TIFF), give the pixel size, read it from an ImageJ TIFF, or draw a line over something of known length such as an existing scale bar or stage micrometer and type its length. The tool picks a 1, 2 or 5 × 10ⁿ length that covers about 15–25 % of the width, or uses yours, and draws the bar with its label in the corner, colour, thickness and size you choose, with an optional box behind it. The PNG keeps the image’s pixel size and DPI, and nothing is uploaded.
- [Gel and western blot lane labeller](https://www.labcanvas.com/tools/gel-lane-labeler) ([Markdown](https://www.labcanvas.com/tools/gel-lane-labeler.md)): Open a gel or blot image, set the number of lanes and the tool splits the image into equal lanes (centres at x₀ + (i + ½) × lane width), which you then drag onto the real lanes. Type a label for each lane, horizontal or angled above it, and add a molecular-weight marker column: pick PageRuler Plus, PageRuler, Precision Plus Protein, GeneRuler 1 kb or NEB 100 bp (band sizes as the manufacturers list them) and drag each mark onto its band, or type your own sizes and positions. Rotate to straighten a tilted gel, crop, and download a PNG, or open it in the LabCanvas editor with the labels as editable text. The image stays in your browser.
- [Plasmid map maker](https://www.labcanvas.com/tools/plasmid-map-maker) ([Markdown](https://www.labcanvas.com/tools/plasmid-map-maker.md)): Enter the plasmid name and size in bp, list the features (name, start, end, strand and type: gene, promoter, origin, resistance marker, MCS or terminator) and any restriction sites, and the tool draws a circular plasmid map with direction arrows, bp tick marks and labels placed outside the circle so they never overlap, plus an optional linear map. You can import the features from a GenBank file (including complement() and join() locations) and find unique restriction sites in the sequence. Download the map as a 300 or 600 dpi PNG, or edit it as vectors in the LabCanvas editor. It opens with pUC19 (2686 bp).
- [Microscopy figure maker: merge and split channels](https://www.labcanvas.com/tools/microscopy-figure-maker) ([Markdown](https://www.labcanvas.com/tools/microscopy-figure-maker.md)): Drop your fluorescence channels (one PNG or TIFF per channel, or one multichannel TIFF, CZI, LIF or ND2) and the tool builds the figure: each channel in its own panel and the merge, with panel letters, channel names in their colours and a scale bar from the file’s pixel size. Colours default to magenta, green and cyan, which stay distinct for colour-blind readers; each channel’s display range is linear (min to black, max to full colour) for the whole image. Drag a box to add a zoom inset with connector lines and its own scale bar, add arrows and text, and export a PNG at 300–1200 dpi, or open it in the LabCanvas editor with the labels editable. Nothing is uploaded.
- [Western blot figure maker, with the uncropped originals](https://www.labcanvas.com/tools/western-blot-figure-maker) ([Markdown](https://www.labcanvas.com/tools/western-blot-figure-maker.md)): Open your blot images (target and loading control, PNG, JPEG or 16-bit TIFF), straighten each one by typing an angle or tracing a band, and drag a crop over the bands you want. The strips are stacked at one width with lane labels above (sample names, + and − rows, group headers with a line across their lanes), kDa ticks from the ladder on the left and the protein names on the right. Contrast is linear only. Download the figure as PNG at 300, 600 or 1200 dpi (or open it in the LabCanvas editor with editable text), and the source data journals ask for: every original, uncropped and unrotated, with each crop outlined and numbered, a list of exposures and crop coordinates, and a ZIP with the untouched files. Nothing is uploaded.
- [Venn diagram and UpSet plot maker](https://www.labcanvas.com/tools/venn-diagram-maker) ([Markdown](https://www.labcanvas.com/tools/venn-diagram-maker.md)): Paste two or more lists, such as gene names or IDs, or type the set sizes and overlaps, and the tool draws a Venn diagram and lists the members of every overlap. Two sets get circles with exactly proportional areas; three sets get the best-fitting circles, with the fit error reported; four and five sets get the classic ellipse diagrams with every region; any number of sets can be shown as an UpSet plot. Download a PNG at 150–600 dpi, the intersections as CSV, or open the diagram in the LabCanvas editor as editable vectors.
- [Plate map maker for 96- and 384-well plates](https://www.labcanvas.com/tools/plate-map-maker) ([Markdown](https://www.labcanvas.com/tools/plate-map-maker.md)): Pick a plate (6, 12, 24, 48, 96 or 384 wells), define your conditions with a colour, concentration, unit and notes, and paint them onto wells by clicking or dragging across wells, rows or columns. Fill helpers place a serial dilution series, samples in duplicate or triplicate (side by side or interleaved), and blanks, standards or controls on the edges; one switch leaves the outer wells as buffer against edge effects, and Randomise shuffles a block of wells with a seed you can write down. Print a dated bench sheet, export a long CSV (well, row, column, condition, concentration, unit) for your plate reader or a plate-shaped grid, download a PNG, or open the plate as an editable figure in LabCanvas. It runs in your browser, keeps your plate, and shares it as a link.
- [Graphical abstract maker with journal sizes](https://www.labcanvas.com/tools/graphical-abstract-maker) ([Markdown](https://www.labcanvas.com/tools/graphical-abstract-maker.md)): Pick the journal and a layout, and the canvas opens at the size the journal asks for, with its rules beside it: Cell Press 1200 × 1200 px with Arial 12–16 pt and no data, Elsevier at least 1328 × 531 px, an ACS TOC graphic 3.25 × 1.75 in, RSC at most 8 × 4 cm at 600 dpi, and Wiley, Angewandte, Springer Nature and MDPI sizes. Four layouts (problem → method → finding, a central idea with satellites, before and after, mechanism → applications) fill the canvas with headings, arrows and placeholders; drop in LabCanvas science icons, edit the labels, and download a PNG or JPEG at the journal’s pixels or dpi. One click sends it to the LabCanvas figure editor with every part still editable.
- [Journal figure checker: resolution, colour, fonts and lines before submission](https://www.labcanvas.com/tools/journal-figure-checker) ([Markdown](https://www.labcanvas.com/tools/journal-figure-checker.md)): Open a figure (TIFF, PNG, JPEG, SVG or PDF), choose the journal (Nature, Science, Cell Press, Elsevier, PLOS, ACS, RSC, Wiley, Springer, PNAS, eLife, Frontiers, MDPI or IEEE), the column width and the kind of figure, and the checker lists what passes, what needs a look and what the journal will send back: the effective DPI at that width against the journal’s minimum for photos, combination figures or line art; the DPI recorded in the file; the size against the height limit; RGB, CMYK or greyscale; bit depth, transparency and colour profile; the format and file size; the JPEG quality, estimated from the file’s quantisation tables; and for SVG and PDF, the font sizes and line widths at the final size, live text versus outlines, embedded fonts and the resolution of placed images. It also looks for colours that red–green colour-blind readers cannot tell apart. It then resamples, converts CMYK to RGB and flattens transparency, saves an LZW TIFF or a PNG with the DPI recorded, and sends the figure to the LabCanvas editor for what pixels cannot fix. The file stays in your browser.
- [Online TikZ editor with live preview](https://www.labcanvas.com/tools/tikz-editor) ([Markdown](https://www.labcanvas.com/tools/tikz-editor.md)): Write or paste TikZ code (a tikzpicture, bare drawing commands or a whole LaTeX document) and the editor typesets it with TeX Live each time you pause typing, so the preview follows your code. Errors point to the line that caused them. Download the figure as a transparent PNG at 300 or 600 dpi with its DPI recorded, copy it, or open it in the LabCanvas editor as editable vector shapes (they stay editable inside LabCanvas; the download is the PNG). pgfplots, circuitikz, tikz-cd, chemfig and the common TikZ libraries are preloaded, pdfLaTeX, LuaLaTeX and XeLaTeX are available, and a library of figures from open-source collections gives you code to start from.
- [Ternary plot maker](https://www.labcanvas.com/tools/ternary-plot-maker) ([Markdown](https://www.labcanvas.com/tools/ternary-plot-maker.md)): Paste three columns of compositions (percentages, fractions or any amounts: each row is rescaled to 100%) and the tool draws a ternary diagram with the first column at the top corner and the other two at the bottom left and right. Add a text column to group rows into series (a name with “region” is filled, as a phase region; “line” or “tie” is joined, as tie lines; anything else is drawn as points) or a fourth number column to colour the points by a value. Download a 300 or 600 dpi PNG or open it in the LabCanvas Graph app.
- [Contour plot and 2D colour map maker](https://www.labcanvas.com/tools/contour-plot-maker) ([Markdown](https://www.labcanvas.com/tools/contour-plot-maker.md)): Paste a grid of Z values (X across the first row, Y down the first column, as Excel lays out a surface) or three columns of scattered X, Y, Z points, and the tool draws a filled contour plot with labelled contour lines and a colour bar, or a smooth 2D colour map. Scattered points are interpolated onto a 60 × 60 grid by Delaunay triangulation (linear, as SciPy’s griddata) and the map is clipped to their convex hull; the levels are chosen as Matplotlib chooses them. Download a 300 or 600 dpi PNG or open it in the LabCanvas Graph app.
- [Polar plot and wind rose maker](https://www.labcanvas.com/tools/polar-plot-maker) ([Markdown](https://www.labcanvas.com/tools/polar-plot-maker.md)): For a wind rose, paste wind directions (degrees from north, where the wind blows from) and speeds, one row per observation: the tool counts them into 16 direction sectors centred on N, NNE, NE … and into speed classes (0.5–2, 2–4, 4–6 and over 6 m/s by default), draws stacked bars as % of all observations, and reports calms apart. For a polar plot, paste angles in the first column and one or more value columns (antenna gain, intensity against angle) and draw them as lines, points, filled areas or rose bars, with 0° at the right or at the top.
- [Raincloud plot maker](https://www.labcanvas.com/tools/raincloud-plot-maker) ([Markdown](https://www.labcanvas.com/tools/raincloud-plot-maker.md)): Paste one column of values per group (names in the first row) and the tool draws a raincloud plot (Allen et al. 2019): for each group a half violin (the “cloud”, a Gaussian kernel density with Scott’s bandwidth, as SciPy), a box plot (median, quartiles, whiskers to 1.5 × IQR) and every value as a jittered point (the “rain”), horizontal or vertical. A summary table gives n, mean, SD, median, quartiles and the kernel bandwidth of each group. Download a 300 or 600 dpi PNG or open it in the LabCanvas Graph app, no code needed.

## Lab calculators

- [Molarity calculator](https://www.labcanvas.com/tools/molarity-calculator) ([Markdown](https://www.labcanvas.com/tools/molarity-calculator.md)): To make a solution of a given molarity, weigh mass (g) = molarity (mol/L) × volume (L) × molar mass (g/mol), dissolve it and make up to the final volume. For 500 mL of 150 mM NaCl (58.44 g/mol) that is 0.150 × 0.500 × 58.44 = 4.383 g. Enter any two of mass, concentration and volume with the molar mass, or pick one of 39 common reagents, and the calculator gives the third.
- [C1V1 = C2V2 dilution calculator](https://www.labcanvas.com/tools/dilution-calculator) ([Markdown](https://www.labcanvas.com/tools/dilution-calculator.md)): C1V1 = C2V2: stock concentration × stock volume = final concentration × final volume, so the stock volume is V1 = C2 × V2 / C1 and the rest is diluent. For 1 mL of 1 mM from a 10 mM stock, V1 = 1 mM × 1 mL / 10 mM = 0.1 mL: 100 µL of stock plus 900 µL of diluent. Enter any three values to get the fourth, in molar, mass, percent or ×-fold units, or plan a serial dilution tube by tube.
- [pH calculator](https://www.labcanvas.com/tools/ph-calculator) ([Markdown](https://www.labcanvas.com/tools/ph-calculator.md)): pH = −log₁₀[H⁺], and at 25 °C pH + pOH = 14, so 0.01 M HCl is pH 2.00 and 0.05 M NaOH is pH 12.70. A weak acid also needs its pKa: 0.1 M acetic acid (pKa 4.76) is pH 2.88. This calculator converts between pH, pOH, [H⁺] and [OH⁻], solves strong and weak acids and bases exactly (including water’s own ions), and gives buffer pH, or the base-to-acid ratio for a target pH, with the Henderson–Hasselbalch equation, pH = pKa + log₁₀([A⁻]/[HA]).
- [Cell doubling time calculator](https://www.labcanvas.com/tools/cell-doubling-time-calculator) ([Markdown](https://www.labcanvas.com/tools/cell-doubling-time-calculator.md)): Doubling time Td = t × ln 2 / ln(N / N₀), where N₀ and N are the cell counts at the start and end of an interval t in exponential growth. Enter two counts and the time, or paste a growth curve to fit ln(N) against time, and get the doubling time, growth rate and doublings per day.
- [Centrifuge RPM to g-force (RCF) calculator](https://www.labcanvas.com/tools/centrifuge-rpm-rcf-calculator) ([Markdown](https://www.labcanvas.com/tools/centrifuge-rpm-rcf-calculator.md)): RCF (× g) = 1.118 × 10⁻⁵ × r × RPM², with r the rotor radius in centimetres; to go the other way, RPM = √(RCF / (1.118 × 10⁻⁵ × r)). For example, 10,000 RPM at a radius of 10 cm is 11,180 × g. Enter the speed or the g-force and the radius, or convert a protocol’s speed to the speed that gives the same g-force on your own rotor.
- [Molar mass calculator](https://www.labcanvas.com/tools/molar-mass-calculator) ([Markdown](https://www.labcanvas.com/tools/molar-mass-calculator.md)): The molar mass of a compound is the sum of the standard atomic weights of its atoms, in g/mol: for water, H₂O = 2 × 1.0080 + 15.999 = 18.015 g/mol. Type a formula, including brackets, hydrates (CuSO4·5H2O or CuSO4*5H2O) and decimal counts, and get the molar mass with each element’s count, atomic weight and mass percentage, using the IUPAC (CIAAW) 2021 standard atomic weights.
- [Protein MW, pI and extinction coefficient calculator](https://www.labcanvas.com/tools/protein-parameter-calculator) ([Markdown](https://www.labcanvas.com/tools/protein-parameter-calculator.md)): Paste a protein sequence (one-letter code or FASTA) to get its molecular weight (the sum of residue masses plus water), theoretical pI, net charge and extinction coefficient ε280 = 5500 × Trp + 1490 × Tyr + 125 × cystine (Pace et al. 1995). Concentration follows from A280: c = A280 / (ε × l), so angiotensin II (ε280 1490 M⁻¹ cm⁻¹) at A280 0.85 in a 1 cm cell is 570.5 µM = 0.597 mg/mL.
- [Ligation calculator: insert mass for any insert:vector molar ratio](https://www.labcanvas.com/tools/ligation-calculator) ([Markdown](https://www.labcanvas.com/tools/ligation-calculator.md)): For a ligation, ng of insert = molar ratio × ng of vector × (insert length in bp / vector length in bp). With 50 ng of a 5,400 bp vector and a 1,200 bp insert, a 3:1 insert:vector ratio needs 33.3 ng of insert; the calculator also gives the pmol of each piece and the amounts for multi-fragment assemblies.
- [Hemocytometer cell count and cell seeding calculator](https://www.labcanvas.com/tools/cell-count-calculator) ([Markdown](https://www.labcanvas.com/tools/cell-count-calculator.md)): Cells per mL = the mean count per large corner square × 10,000 × the dilution factor; with equal volumes of cells and trypan blue the dilution is 2. Viability is live cells ÷ (live + dead) × 100. The calculator then gives the volume of suspension and medium to seed a set number of cells in each well.
- [Primer Tm calculator (nearest-neighbour, with salt and Mg²⁺)](https://www.labcanvas.com/tools/primer-tm-calculator) ([Markdown](https://www.labcanvas.com/tools/primer-tm-calculator.md)): Paste one or two primers (5′→3′) and the calculator gives each primer’s melting temperature from the SantaLucia 1998 nearest-neighbour parameters, corrected for your oligo concentration, Na⁺/K⁺, Mg²⁺ and dNTPs, with the Tm difference between the primers, GC content, molar mass, ΔH°, ΔS°, the G/C count at the 3′ end and the longest repeats.
- [DNA/RNA concentration and copy number calculator](https://www.labcanvas.com/tools/dna-concentration-calculator) ([Markdown](https://www.labcanvas.com/tools/dna-concentration-calculator.md)): DNA concentration (ng/µL) = A260 × 50 for dsDNA (40 for RNA, 38 for ssDNA oligos) × dilution ÷ path length in cm, with A260/A280 and A260/A230 for purity; copies per µL = concentration (g/µL) ÷ molar mass × 6.022 × 10²³. An A260 of 0.75 is 37.5 ng/µL, or 1.137 × 10¹⁰ copies/µL for a 3,000 bp plasmid. The calculator also gives nM and lays out a serial dilution series for a qPCR standard curve.
- [RHE converter: reference electrode to RHE](https://www.labcanvas.com/tools/rhe-calculator) ([Markdown](https://www.labcanvas.com/tools/rhe-calculator.md)): To convert a potential to the reversible hydrogen electrode (RHE) scale, E(RHE) = E(ref) + E°(ref) + 0.059 × pH at 25 °C, where E°(ref) is the reference electrode’s potential vs SHE (0.199 V for Ag/AgCl in saturated KCl). For 0.45 V vs Ag/AgCl at pH 14: 0.45 + 0.199 + 0.05916 × 14 = 1.477 V vs RHE, an OER overpotential of 1.477 − 1.23 = 0.247 V. Subtract i × Rs first for the iR-free potential.
- [Faradaic efficiency calculator for gas and liquid products](https://www.labcanvas.com/tools/faradaic-efficiency-calculator) ([Markdown](https://www.labcanvas.com/tools/faradaic-efficiency-calculator.md)): Faradaic efficiency is the fraction of the charge passed that ends up in a product: FE = z·n·F / Q, with z the electrons per molecule, n the moles of product, F = 96 485 C/mol and Q the charge. For a gas product measured on-line by GC, the moles come from its volume fraction x in the outlet flow v, so FE = z·F·x·v·p / (R·T·I), with I the total current.
- [Chemical equation balancer](https://www.labcanvas.com/tools/chemical-equation-balancer) ([Markdown](https://www.labcanvas.com/tools/chemical-equation-balancer.md)): Type an unbalanced equation such as Fe + O2 -> Fe2O3 and the balancer returns the smallest whole-number coefficients, here 4Fe + 3O₂ → 2Fe₂O₃, with a table showing that every element (and the charge) is the same on both sides. It handles brackets, hydrates (CuSO4·5H2O), ions (Fe3+, SO4^2-) and electrons (e-) for redox half-equations, solves the balance exactly with fractions rather than trial and error, and tells you when an equation cannot be balanced or has no unique balance. The result is typeset with mhchem and can be copied as text or LaTeX \ce{…}, or downloaded as a PNG at 300 or 600 dpi.
- [Concentration unit converter](https://www.labcanvas.com/tools/concentration-converter) ([Markdown](https://www.labcanvas.com/tools/concentration-converter.md)): To convert molarity to mg/mL, multiply by the molar mass: mg/mL = mol/L × g/mol (1 mg/mL = 1 g/L); divide to go back. For example, 150 mM NaCl (58.44 g/mol) is 0.150 × 58.44 = 8.766 mg/mL = 0.8766 % w/v = 8766 ppm. Enter one concentration and the molar mass, and every other unit appears at once: M, mg/mL, % w/v, % w/w, ppm, molality, mole fraction and normality.
- [ECSA calculator: double-layer capacitance, ECSA and roughness factor](https://www.labcanvas.com/tools/ecsa-calculator) ([Markdown](https://www.labcanvas.com/tools/ecsa-calculator.md)): The electrochemically active surface area (ECSA) is the double-layer capacitance Cdl divided by a specific capacitance Cs: ECSA = Cdl/Cs. Record CVs at several scan rates in a potential window with no Faradaic current, read the anodic and cathodic current at one potential, and plot half their difference, Δi/2, against the scan rate: the slope is Cdl. McCrory et al. (2013) used Cs = 0.040 mF/cm² in 1 M NaOH and 0.035 mF/cm² in 1 M H₂SO₄, so Cdl = 0.1428 mF gives an ECSA of 3.57 cm² in alkaline solution; divided by the geometric area, 0.196 cm², that is a roughness factor of 18.2.
- [Turnover frequency (TOF) and TON calculator](https://www.labcanvas.com/tools/turnover-frequency-calculator) ([Markdown](https://www.labcanvas.com/tools/turnover-frequency-calculator.md)): Turnover frequency is the number of molecules each active site converts per unit time: TOF = rate / number of active sites, in s⁻¹. In electrocatalysis the rate comes from the current, TOF = I·FE/(n·F·N), or per area TOF = j/(n·F·Γ) with Γ the sites per cm²: 10 mA/cm² of oxygen evolution (n = 4) on 1 nmol/cm² of sites is 25.9 s⁻¹. In heterogeneous catalysis TOF is the moles of product per second divided by the moles of active sites, often counted from the metal loading and its dispersion. The turnover number (TON) is the product per site over the whole run. A TOF is only as good as its site count, so state how the sites were counted.
- [Battery capacity calculator: theoretical mAh/g, C-rate and energy density](https://www.labcanvas.com/tools/battery-capacity-calculator) ([Markdown](https://www.labcanvas.com/tools/battery-capacity-calculator.md)): The theoretical specific capacity of an electrode material is Q = n·F/(3.6·M) mAh/g: n electrons (Li⁺) per formula unit, F = 96 485 C/mol, M the molar mass and 3.6 coulombs per mAh. For LiFePO₄ (n = 1, M = 157.75 g/mol) that is 169.9 mAh/g; graphite to LiC₆ gives 371.9 mAh/g per gram of carbon, and silicon to Li₁₅Si₄ 3579 mAh/g. The current at a C-rate is the rate times the capacity (10 mg of LiFePO₄ at 0.5 C: 0.85 mA for 2 h), the capacity you measure is current × time, and the specific energy is the specific capacity times the average voltage: 157.25 mAh/g × 3.4 V = 534.7 Wh/kg of active material.
- [Beer–Lambert law calculator: concentration from absorbance (A = εlc)](https://www.labcanvas.com/tools/beer-lambert-law-calculator) ([Markdown](https://www.labcanvas.com/tools/beer-lambert-law-calculator.md)): The Beer–Lambert law says that absorbance is proportional to concentration: A = ε·l·c, with ε the molar absorption coefficient (M⁻¹ cm⁻¹), l the path length (cm) and c the concentration (mol/L). So c = A/(ε·l): an NADH solution with A340 = 0.415 in a 1 cm cuvette (ε = 6220 M⁻¹ cm⁻¹) is 66.7 µM. Choose which of the four to calculate, enter the other three in any units (M, mM, µM, mg/mL, µg/mL; cm or mm; ε per mole or per gram, joined by the molar mass), or enter the transmittance instead of the absorbance (A = 2 − log₁₀ %T).

## Data analysis

- [qPCR delta delta Ct (ΔΔCt) calculator](https://www.labcanvas.com/tools/qpcr-calculator) ([Markdown](https://www.labcanvas.com/tools/qpcr-calculator.md)): Fold change by the delta delta Ct (Livak) method is 2^−ΔΔCt, where ΔCt = Ct(target) − Ct(reference gene) and ΔΔCt = ΔCt(sample) − ΔCt(control). A ΔΔCt of −3.133 gives 2^3.133 = 8.77-fold higher expression. Paste your Ct values with replicates and get ΔCt, ΔΔCt, fold change with its SD range, the Pfaffl ratio when efficiencies differ from 100 %, a chart and a CSV.
- [Western blot and SDS-PAGE molecular weight calculator](https://www.labcanvas.com/tools/western-blot-mw-calculator) ([Markdown](https://www.labcanvas.com/tools/western-blot-mw-calculator.md)): Upload a photo of your gel or blot, click the ladder bands (their sizes fill in from the ladder you choose), then click your sample bands. The calculator fits log₁₀(molecular weight) against migration distance and reports each band’s estimated size in kDa, with R², an annotated image and a CSV. It also works with distances typed in by hand.
- [ELISA standard curve calculator with 4PL curve fitting](https://www.labcanvas.com/tools/elisa-standard-curve-analyzer) ([Markdown](https://www.labcanvas.com/tools/elisa-standard-curve-analyzer.md)): Enter your standards (concentration and OD, with replicates) and your samples’ ODs and dilution factors. The calculator fits a four-parameter logistic (4PL) standard curve, or a linear or log-log line, subtracts the blank, and calculates each sample’s concentration, flagging values outside the standard range. It works for sandwich and competitive ELISAs. You get R², the fitted parameters, a chart and a CSV.
- [IC50 and EC50 calculator with a four-parameter logistic fit](https://www.labcanvas.com/tools/ic50-calculator) ([Markdown](https://www.labcanvas.com/tools/ic50-calculator.md)): Paste concentrations and responses (with replicates) and the calculator fits a four-parameter logistic (Hill) curve on a log-concentration axis. It gives the relative IC50 or EC50 with its 95% confidence interval, the Hill slope, the top and bottom plateaus and R², plus the absolute IC50 when you normalise to 0% and 100% controls, with a chart and a CSV.
- [XRD crystallite size (Scherrer) and d-spacing (Bragg) calculator](https://www.labcanvas.com/tools/xrd-scherrer-calculator) ([Markdown](https://www.labcanvas.com/tools/xrd-scherrer-calculator.md)): Crystallite size D = Kλ / (β cos θ), where β is the peak’s full width at half maximum in radians, θ is half the 2θ peak position, λ the X-ray wavelength and K ≈ 0.9; the d-spacing comes from Bragg’s law, d = nλ / 2 sin θ. Paste your peak positions and widths to get the size and d-spacing of every peak and their mean, with the instrument’s broadening removed if you enter it.
- [Supercapacitor specific capacitance, energy density and battery C-rate calculator](https://www.labcanvas.com/tools/supercapacitor-calculator) ([Markdown](https://www.labcanvas.com/tools/supercapacitor-calculator.md)): Specific capacitance from a cyclic voltammogram is C = ∮I dV / (2·m·v·ΔV): the area of the CV loop divided by twice the active mass m, the scan rate v and the potential window ΔV. From a galvanostatic discharge it is C = I·Δt / (m·ΔV), with I the current, Δt the discharge time and ΔV the window without the IR drop; 1 mA for 100 s over 0.95 V on 2 mg gives 52.6 F/g. Paste a CV loop or a discharge curve and the calculator does the integral for you. For a two-electrode cell the energy density is E = ½·C·ΔV² and the power density P = E / Δt; for a battery, the current at n C is n × the capacity and a full charge or discharge takes 1/n hours.
- [Tauc plot band gap calculator (UV–vis)](https://www.labcanvas.com/tools/tauc-plot-band-gap-calculator) ([Markdown](https://www.labcanvas.com/tools/tauc-plot-band-gap-calculator.md)): Convert each wavelength to photon energy (E = 1240/λ, E in eV, λ in nm), plot (αhν)² against hν for a direct allowed transition or (αhν)^½ for an indirect one, fit a straight line to the steep part of the absorption edge and extend it to the energy axis: the intercept is the optical band gap Eg. Paste your absorbance (or diffuse reflectance, converted with Kubelka–Munk) and the calculator finds the straight part of the edge, fits it and gives Eg with its standard error and 95% confidence interval.
- [Graphene Raman layer checker: monolayer, few-layer or multilayer](https://www.labcanvas.com/tools/graphene-raman-layer-calculator) ([Markdown](https://www.labcanvas.com/tools/graphene-raman-layer-calculator.md)): Monolayer graphene on Si/SiO₂ has a single-Lorentzian 2D band with a full width at half maximum of 35 cm⁻¹ or less and a 2D peak at least twice as high as the G peak: these are the UK National Physical Laboratory (NPL) criteria. Enter the 2D width, the I(2D)/I(G) ratio and the 2D line shape from your fit, and the checker compares them with the NPL criteria and the published layer trends. It is an indication, not proof.
- [Tafel slope and exchange current density calculator](https://www.labcanvas.com/tools/tafel-slope-calculator) ([Markdown](https://www.labcanvas.com/tools/tafel-slope-calculator.md)): A Tafel slope is found by plotting the overpotential η against log10 of the current density and fitting a straight line, η = a + b·log10|j|, over the linear part: b is the Tafel slope in mV per decade, and where the line reaches η = 0 it gives the exchange current density, log10 j₀ = −a/b. Paste your polarisation data, pick the range, and the calculator returns b, j₀ and R² with the plot.
- [Coulombic efficiency calculator: CE per cycle, average CE and capacity retention](https://www.labcanvas.com/tools/coulombic-efficiency-calculator) ([Markdown](https://www.labcanvas.com/tools/coulombic-efficiency-calculator.md)): Coulombic efficiency (CE) is the capacity a cell gives back divided by the capacity put in during the same cycle. For a cathode half-cell or a full cell that is discharge / charge; for a lithium-metal or anode half-cell (Li||Cu) it is stripping / plating, the charge capacity over the discharge capacity. If every cycle keeps the same CE and nothing replaces the lost lithium, the capacity left after n cycles is CEⁿ: 99.7 % CE falls to 80 % after about 74 cycles, 99.9 % after about 223. Paste your cycling data to get the CE of every cycle, the average over the cycles you choose, the first-cycle loss and the retention.
- [Ionic conductivity calculator from impedance (EIS)](https://www.labcanvas.com/tools/ionic-conductivity-calculator) ([Markdown](https://www.labcanvas.com/tools/ionic-conductivity-calculator.md)): Ionic conductivity from impedance is σ = L / (R·A), with L the thickness of the electrolyte between two blocking electrodes, A the electrode area and R its resistance, read from the Nyquist plot where the impedance meets the real axis. For a solid electrolyte, fit a circle through the arc: its high-frequency end gives the bulk resistance when the bulk arc lies above the measured frequencies, and its low-frequency end the total (bulk + grain boundary). With several temperatures, the slope of ln(σT) or log σ against 1000/T gives the activation energy Ea.
- [BET surface area calculator with the consistency (Rouquerol) criteria](https://www.labcanvas.com/tools/bet-surface-area-calculator) ([Markdown](https://www.labcanvas.com/tools/bet-surface-area-calculator.md)): The BET surface area is the monolayer capacity n_m times Avogadro’s number times the cross-sectional area of the adsorbate (0.162 nm² for N₂ at 77 K). n_m and the BET constant C come from a straight-line fit of 1/[n((p₀/p) − 1)] against p/p₀, usually between 0.05 and 0.30: n_m = 1/(slope + intercept) and C = 1 + slope/intercept. For microporous materials such as MOFs and activated carbons, pick the range with the consistency (Rouquerol) criteria: C positive, n(1 − p/p₀) rising over the range, and the p/p₀ at n_m inside it. Paste your isotherm and the calculator does the fit, checks the criteria and can find the longest range that passes them.
- [Microscope pixel size calculator: µm per pixel and ImageJ Set Scale](https://www.labcanvas.com/tools/microscope-pixel-size-calculator) ([Markdown](https://www.labcanvas.com/tools/microscope-pixel-size-calculator.md)): Pixel size in the specimen = camera pixel size × binning ÷ total magnification: a 6.5 µm camera pixel behind a 20× objective covers 0.325 µm (3.077 pixels per µm). To measure it instead, photograph a stage micrometer and divide the known distance by its length in pixels; for an SEM or TEM image, divide the horizontal field width by the image width in pixels. The calculator gives µm per pixel, pixels per µm, the field of view, whether the pixel meets Nyquist sampling, and what to type into ImageJ’s Analyze › Set Scale.
- [ASTM E112 grain size number calculator](https://www.labcanvas.com/tools/astm-grain-size-calculator) ([Markdown](https://www.labcanvas.com/tools/astm-grain-size-calculator.md)): The ASTM E112 grain size number is G = 3.321928·log₁₀(N_A) − 2.954, with N_A the number of grains per mm² (1 ÷ the mean grain area in mm²), or G = −6.643856·log₁₀(ℓ̄) − 3.288 from the mean lineal intercept ℓ̄ in mm. Both follow from the definition N = 2^(G − 1) grains per square inch at 100×, so a higher G means smaller grains: a mean intercept of 20 µm is G 8.0. Enter a mean grain area from image analysis, a grain count, an intercept length or G itself.
- [Michaelis–Menten calculator: Km, Vmax, kcat and kcat/Km](https://www.labcanvas.com/tools/michaelis-menten-calculator) ([Markdown](https://www.labcanvas.com/tools/michaelis-menten-calculator.md)): Paste substrate concentrations and initial rates (with replicates) and the calculator fits v = Vmax·[S]/(Km + [S]) by nonlinear least squares. It gives Km and Vmax with standard errors, 95% confidence intervals and R², kcat and kcat/Km when you enter the enzyme concentration, the fitted curve over your data, and a Lineweaver–Burk plot of the same data for comparison. A substrate-inhibition model can be fitted and tested against plain Michaelis–Menten.
- [BCA and Bradford protein assay standard curve calculator](https://www.labcanvas.com/tools/protein-assay-standard-curve) ([Markdown](https://www.labcanvas.com/tools/protein-assay-standard-curve.md)): Enter the absorbance of your BSA standards (A562 for BCA, A595 for Bradford, with replicates) and of your samples with their dilution factors. The calculator subtracts the blank, fits a quadratic or linear standard curve, reads each sample’s protein concentration off the curve, multiplies it by the dilution factor and flags samples outside the standard range. Preset standard series for the BCA (25–2000 µg/mL) and Bradford (125–2000 µg/mL) assays can be edited.
- [Kaplan–Meier survival curve maker with log-rank test](https://www.labcanvas.com/tools/kaplan-meier-plot) ([Markdown](https://www.labcanvas.com/tools/kaplan-meier-plot.md)): Paste one row per subject with the time, the event (1 = event, 0 = censored) and, optionally, a group. The tool draws the Kaplan–Meier (product-limit) survival curves with censoring ticks, a 95% confidence band and the number-at-risk table under the plot. It reports the median survival with its 95% confidence interval, Greenwood standard errors, the log-rank test P value between groups and the hazard ratio of two groups, and exports the figure as PNG (about 300 or 600 dpi) and the tables as CSV.
- [Volcano plot maker for differential expression](https://www.labcanvas.com/tools/volcano-plot-maker) ([Markdown](https://www.labcanvas.com/tools/volcano-plot-maker.md)): Paste a differential-expression table (gene, log2 fold change, p-value, and the adjusted p-value if you have it) from DESeq2, edgeR, limma, proteomics or any t-tests. Set the fold-change and p or FDR thresholds, and the tool draws a volcano plot of log2 fold change against −log10 p, colours up-regulated, down-regulated and non-significant genes, labels the top genes and counts the hits. If you only have raw p-values it computes Benjamini–Hochberg adjusted p-values. Download the plot as a 300 or 600 dpi PNG and the significant genes as CSV.
- [Heatmap maker with hierarchical clustering](https://www.labcanvas.com/tools/heatmap-maker) ([Markdown](https://www.labcanvas.com/tools/heatmap-maker.md)): Paste a matrix with row and column labels, such as genes by samples, and the tool draws a heatmap. It can scale each row to z-scores, cluster rows and columns by average-linkage hierarchical clustering with Euclidean or 1 − Pearson correlation distance and draw the dendrograms, colour the cells with a colour-blind-safe scale (viridis, cividis, blue–white–red or purple–white–orange) and show the values in the cells. Download the heatmap as a 300 or 600 dpi PNG and the reordered matrix as CSV.
- [Box plot and violin plot maker with statistics](https://www.labcanvas.com/tools/box-plot-maker) ([Markdown](https://www.labcanvas.com/tools/box-plot-maker.md)): Paste your groups (one column each, straight from Excel) and the tool draws a box plot (median, quartiles, 1.5 × IQR whiskers and outliers) or a violin plot (Gaussian kernel density) with every data point shown. It tests the groups: Welch’s t-test or the Mann–Whitney U test for two groups, one-way ANOVA with Tukey–Kramer or Kruskal–Wallis with Dunn’s test for three or more, and adds significance brackets with stars or p-values. A summary table gives n, mean, SD, SEM, median and IQR, and the plot downloads as a PNG at 300 or 600 dpi (or opens in the LabCanvas editor as editable vectors).
- [Which statistical test should I use?](https://www.labcanvas.com/tools/statistical-test-chooser) ([Markdown](https://www.labcanvas.com/tools/statistical-test-chooser.md)): Answer a few questions about your experiment: what you want to do (compare groups, relate two variables, predict an outcome or compare survival), what kind of data you measured, how many groups, whether they are independent or paired, whether the data look normal and how large the sample is. The guide recommends the test, explains why, lists its assumptions and gives the non-parametric (or parametric) alternative. It covers t-tests, Mann–Whitney, Wilcoxon signed-rank, one-way and repeated-measures ANOVA, Kruskal–Wallis, Friedman, chi-square, Fisher’s exact, McNemar, Pearson and Spearman correlation, linear and logistic regression and the log-rank test, with a full table below.
- [Sample size calculator (power analysis)](https://www.labcanvas.com/tools/sample-size-calculator) ([Markdown](https://www.labcanvas.com/tools/sample-size-calculator.md)): For a two-sample t test with a medium effect (Cohen’s d = 0.5), α = 0.05 two-sided and 80% power you need 64 participants per group, 128 in total. Choose the test (two-sample t, paired t, two proportions, one-way ANOVA or correlation), enter the expected effect as an effect size or as means and SDs, proportions or group means, and set α, power, one- or two-sided and the allocation ratio. The calculator gives the smallest sample size that reaches the target power, or the power of a sample size you already have, with a power curve. t tests use the exact noncentral t distribution, the same calculation as G*Power and R’s pwr.t.test.
- [Nyquist plot maker and EIS equivalent-circuit fitting](https://www.labcanvas.com/tools/nyquist-plot-eis-fitting) ([Markdown](https://www.labcanvas.com/tools/nyquist-plot-eis-fitting.md)): Paste your impedance spectrum (frequency, Z′ and Z″, or an EC-Lab, Gamry, CH Instruments or Autolab export) and you get a Nyquist plot with equal axes and a Bode plot, an equivalent circuit fitted by complex nonlinear least squares (Randles, CPE, Warburg, two-arc, coating and Gerischer circuits, or your own in impedance.py notation), every parameter with its standard error, χ² and reduced χ², and a Kramers–Kronig check of the data. The fit minimises Σ[(Z′ − Z′fit)² + (Z″ − Z″fit)²]/|Z|² over all frequencies.
- [Cyclic voltammetry analyser: peaks, ΔEp, E½ and Randles–Ševčík D](https://www.labcanvas.com/tools/cyclic-voltammetry-analyzer) ([Markdown](https://www.labcanvas.com/tools/cyclic-voltammetry-analyzer.md)): Paste potential and current (one or several scan rates, or an EC-Lab, Gamry, CH Instruments or Autolab export) and the analyser finds the anodic and cathodic peaks above a linear baseline, gives Epa, Epc, ipa, ipc, ΔEp = Epa − Epc, E½ = (Epa + Epc)/2 and the peak ratio, and over several scan rates fits ip against √v to get the diffusion coefficient from the Randles–Ševčík equation, ip = 0.4463 nFAC (nFvD/RT)^½, with the log–log slope that tells diffusion (0.5) from adsorption (1).
- [Battery cycling plot: capacity retention and coulombic efficiency](https://www.labcanvas.com/tools/battery-cycling-plot) ([Markdown](https://www.labcanvas.com/tools/battery-cycling-plot.md)): Paste the capacities per cycle from your cycler (cycle, charge capacity, discharge capacity), or its raw time–voltage–current export, enter the active-material mass, and you get specific capacity in mAh/g (capacity in mAh × 1000 / mass in mg), capacity retention (discharge capacity of each cycle / that of the reference cycle) and coulombic efficiency (discharge / charge, or charge / discharge for an anode half-cell) for every cycle, plotted against cycle number on two axes, with the first-cycle loss, the mean CE and the cycles to 80 % retention.
- [Peak fitting online for Raman, XRD, FTIR and XPS spectra](https://www.labcanvas.com/tools/peak-fitting-online) ([Markdown](https://www.labcanvas.com/tools/peak-fitting-online.md)): Paste a spectrum (two columns, or drop a CSV, JCAMP-DX or SPC file) and the tool finds the peaks, including shoulders from the second derivative, and fits them all at once with a straight-line baseline: Gaussian, Lorentzian, Voigt or pseudo-Voigt shapes by nonlinear least squares. You get a table of centre, height, area, % of the total area and FWHM, each ± standard error, with the fitted components drawn under the spectrum. A Gaussian peak’s FWHM is 2√(2 ln 2) σ = 2.355 σ; a Lorentzian’s is 2γ.
- [XPS peak fitting online (C 1s, O 1s, N 1s deconvolution)](https://www.labcanvas.com/tools/xps-peak-fitting) ([Markdown](https://www.labcanvas.com/tools/xps-peak-fitting.md)): Paste a charge-corrected XPS region (binding energy and counts), list the chemical states you expect (for C 1s: C–C/C–H 284.8, C–O 286.3, C=O 287.8, O–C=O 289.0 eV) or let the tool find the peaks, and it fits them together with a linear background as pseudo-Voigt GL(30) peaks of one shared FWHM, the usual constraints for a C 1s region. You get each component’s binding energy, area, % of the total area and FWHM ± SE, drawn as filled components on a reversed binding-energy axis. Atomic ratios between elements also need the relative sensitivity factors.
- [Bayesian t test and Bayes factor calculator](https://www.labcanvas.com/tools/bayesian-t-test-calculator) ([Markdown](https://www.labcanvas.com/tools/bayesian-t-test-calculator.md)): Paste two columns (two independent groups, or the same subjects measured twice) and the calculator gives the Bayes factor BF₁₀ of a Bayesian t test with the default JZS prior (a Cauchy prior on the effect size δ with width r = √2/2, as in JASP and the BayesFactor R package), says how strong the evidence is (anecdotal, moderate, strong, very strong, extreme), and shows the posterior of δ with its 95% credible interval and a robustness plot of BF₁₀ against the prior width. BF₁₀ = 17 means the data are 17 times more likely if there is a difference than if there is none.
- [Meta-analysis forest plot maker](https://www.labcanvas.com/tools/forest-plot-maker) ([Markdown](https://www.labcanvas.com/tools/forest-plot-maker.md)): Paste one row per study (events and totals in each group, means, SDs and Ns, or an effect with its 95% confidence interval or standard error) and the tool pools them by inverse-variance meta-analysis: the random-effects estimate (REML, DerSimonian–Laird or Paule–Mandel τ²) and the fixed-effect one (Mantel–Haenszel for counts), with heterogeneity (I², τ², Cochran’s Q), the 95% prediction interval and Egger’s test, drawn as a forest plot and a funnel plot. Ratios (risk ratios, odds ratios, hazard ratios) are pooled on the log scale.
- [Mott–Schottky analyzer: flat-band potential and donor density](https://www.labcanvas.com/tools/mott-schottky-analyzer) ([Markdown](https://www.labcanvas.com/tools/mott-schottky-analyzer.md)): A Mott–Schottky plot is 1/C² against the applied potential, with C the space-charge capacitance per unit area. In the depletion region it is a straight line, 1/C² = 2/(e·ε·ε₀·N)·(E − E_fb − kT/e) for an n-type semiconductor, so the flat-band potential is the x-intercept minus kT/e (25.7 mV at 25 °C) and the donor density is N_D = 2/(e·ε·ε₀·slope); a negative slope means p-type, with E_fb = x-intercept + kT/e. Paste capacitance against potential (one or several frequencies) and the analyzer fits the straight part, gives E_fb and N with standard errors, and converts E_fb to the RHE scale.
- [Williamson–Hall plot calculator: crystallite size and microstrain from XRD](https://www.labcanvas.com/tools/williamson-hall-plot) ([Markdown](https://www.labcanvas.com/tools/williamson-hall-plot.md)): A Williamson–Hall plot separates the two causes of XRD peak broadening. Plot β cos θ against 4 sin θ for every peak (β the FWHM in radians after removing the instrument’s width, θ half the peak position 2θ) and fit a straight line: in the uniform deformation model, β cos θ = Kλ/D + 4ε sin θ, so the intercept gives the crystallite size D = Kλ/intercept and the slope is the microstrain ε. Paste your peak list (2θ, FWHM, hkl) and the calculator draws the plot, fits the line and gives D and ε with 95 % confidence intervals, using the same λ, K and instrumental correction as the Scherrer calculator.
- [Adsorption isotherm fitting: Langmuir, Freundlich, Sips and Temkin](https://www.labcanvas.com/tools/adsorption-isotherm-fitting) ([Markdown](https://www.labcanvas.com/tools/adsorption-isotherm-fitting.md)): Paste your equilibrium concentrations Ce and uptakes qe (or C0 and Ce of batch experiments with the volume and adsorbent mass) and the tool fits the Langmuir isotherm qe = qm·KL·Ce/(1 + KL·Ce), the Freundlich isotherm qe = KF·Ce^(1/n), and optionally Sips and Temkin, by nonlinear least squares on qe itself. It gives each parameter with its standard error and 95 % confidence interval, R², adjusted R², RMSE, AIC and AICc to compare the models, the Langmuir separation factor RL = 1/(1 + KL·C0), and the fitted curves on one plot. Linearised plots (Ce/qe against Ce, ln qe against ln Ce) change how the errors are weighted and bias the parameters, so they are shown only for comparison.
- [Photocatalytic degradation kinetics: rate constant k, half-life and % degradation](https://www.labcanvas.com/tools/photocatalytic-degradation-kinetics) ([Markdown](https://www.labcanvas.com/tools/photocatalytic-degradation-kinetics.md)): For photocatalytic degradation of a dye or pollutant, plot ln(C0/C) against irradiation time: for pseudo-first-order kinetics the points fall on a straight line whose slope is the apparent rate constant k_app, the half-life is ln 2/k_app, and the degradation is (1 − C/C0) × 100 %. C0 is the concentration when the light is switched on, after the dark adsorption–desorption step, not the concentration you started with. Paste time and concentration (or absorbance, proportional to concentration by Beer–Lambert) and the calculator finds C0 at light-on, fits the line, and gives k_app and t½ with 95 % confidence intervals, the removal in the dark and under light, and a second-order fit for comparison.
