# Mott–Schottky analyzer: flat-band potential and donor density

> Paste capacitance vs potential for a 1/C² plot, flat-band potential (x-intercept − kT/e) and donor or acceptor density, also vs RHE. Free.

URL: https://www.labcanvas.com/tools/mott-schottky-analyzer

A Mott–Schottky plot is 1/C² against the applied potential, with C the space-charge capacitance per unit area. In the depletion region it is a straight line, 1/C² = 2/(e·ε·ε₀·N)·(E − E_fb − kT/e) for an n-type semiconductor, so the flat-band potential is the x-intercept minus kT/e (25.7 mV at 25 °C) and the donor density is N_D = 2/(e·ε·ε₀·slope); a negative slope means p-type, with E_fb = x-intercept + kT/e. Paste capacitance against potential (one or several frequencies) and the analyzer fits the straight part, gives E_fb and N with standard errors, and converts E_fb to the RHE scale.

## Quick answer

- **What it does:** Fits a straight line to 1/C² against potential over the linear (depletion) region and gives the flat-band potential and the donor or acceptor density for each frequency, with standard errors.
- **Formula:** 1/C² = ±2/(e·ε·ε0·N)·(E − Efb ∓ kT/e);  Efb = E0 ∓ kT/e (E0 the x-intercept);  N = 2/(e·ε·ε0·A²·|slope|)
- **Example:** The built-in synthetic n-type film (ε = 86) at 1 kHz: the line from 0.077 to 0.977 V vs RHE has a slope of 8.525 × 10¹⁰ cm⁴ F⁻² V⁻¹ and meets the axis at 0.0748 V, so E_fb = 0.0748 − 0.0257 = 0.0491 V vs RHE and N_D = 1.92 × 10¹⁹ cm⁻³.

Free, in the browser, no account needed. Updated 2026-11-23.

## Features

- Paste potential and capacitance (C per cm² or of the whole electrode, in F, mF, µF or nF), 1/C², or Z″ with the frequency (C = 1/(2πf|Z″|)); units read from the column names
- Several frequencies at once: one Mott–Schottky line per frequency, compared in a table (E_fb should not depend on the frequency)
- Linear region found automatically (the longest run without significant curvature, as in the LabCanvas Graph app) or typed
- Flat-band potential E_fb = x-intercept ∓ kT/e with its standard error, n- or p-type from the sign of the slope
- Donor or acceptor density N = 2/(e ε ε₀ A² |slope|) with its standard error; ε from a referenced table (Si, GaAs, CdTe, ZnSe, rutile TiO₂) or your own value
- Potentials converted to the RHE scale with the RHE converter’s reference electrodes and the pH
- Mott–Schottky plot as PNG (300 or 600 dpi), results and data as CSV, a methods sentence, and the same analysis in the Graph app; nothing is uploaded

## How to use it

1. **Paste or drop your data**: Columns: potential and capacitance, with a frequency column if you measured several frequencies (rows one under another). A header such as E (V vs Ag/AgCl), C (µF/cm²), f (Hz) gives the units; without one, choose what the second column holds.
2. **Enter the semiconductor and the electrode**: Pick the material for ε or type ε, and enter the electrode area if the capacitance is for the whole electrode.
3. **Check the frequency and the linear region**: Choose the frequency to report and look at the plot: keep the straight part of 1/C², away from the bend near E_fb and from the high-bias end.
4. **Choose the potential scale**: Keep the measured scale, or pick the reference electrode and the pH to report E_fb against RHE.
5. **Read and export**: Read E_fb, N and the type, compare the frequencies, and copy the results, the methods sentence or the plot.

## At a glance

| | |
| --- | --- |
| Model | \(1/C^2 = \pm 2/(e\,\varepsilon\,\varepsilon_0 N)\,(E - E_\mathrm{fb} \mp kT/e)\), C per cm² |
| Gives | E_fb ± SE, N_D or N_A ± SE, type, slope, region, R²; per frequency |
| Fit | Least squares over the linear region (automatic: longest run without significant curvature; or typed) |
| Input | E with C (per cm² or whole electrode), 1/C², or Z″ with the frequency; optional frequency column |
| Constants | CODATA 2018 (NIST): e, k, ε₀ |
| Output | Mott–Schottky plot (PNG 300/600 dpi), CSV, methods sentence, Graph app |

## How it works

$$\frac{1}{C_\mathrm{sc}^2} = \frac{2}{e\,\varepsilon\,\varepsilon_0\,A^2\,N_\mathrm{D}}\left(E - E_\mathrm{fb} - \frac{kT}{e}\right)$$

**The Mott–Schottky equation.** At a semiconductor–electrolyte junction under depletion, the space-charge layer behaves as a capacitor whose thickness grows with the band bending, so \(1/C_\mathrm{sc}^2\) rises linearly with the potential. Gelderman, Lee and Donne (2007) write it as above for an n-type electrode, with \(C_\mathrm{sc}\) the space-charge capacitance, \(A\) the electrode area, \(\varepsilon\) the relative permittivity of the semiconductor, \(\varepsilon_0\) the vacuum permittivity, \(N_\mathrm{D}\) the donor density, \(e\) the elementary charge, \(k\) Boltzmann’s constant and \(T\) the temperature; the same relation is derived in Bard and Faulkner’s textbook (section 18.2). For a p-type electrode the slope is negative and the sign of \(kT/e\) changes: \(1/C^2 = -2/(e\,\varepsilon\,\varepsilon_0\,A^2 N_\mathrm{A})\) \({}\times (E - E_\mathrm{fb} + kT/e)\).

**What the analyzer computes.** It converts every row to the capacitance per cm² (dividing by the area when the capacitance is for the whole electrode; from impedance as \(C = 1/(2\pi f |Z''|)\), a series RC), takes \(y = 1/C^2\) in cm⁴ F⁻², and fits \(y = a + bE\) by least squares over the linear region. The x-intercept is \(E_0 = -a/b\); then

$$E_\mathrm{fb} = E_0 \mp \frac{kT}{e}, \qquad N = \frac{2}{e\,\varepsilon\,\varepsilon_0\,|b|}$$

(minus for n-type, plus for p-type, the type from the sign of \(b\)), with \(\varepsilon_0\) in F/cm so that \(N\) is in cm⁻³. With the capacitance per cm² the area is already in \(C\), which is the same as the \(A^2\) in the formula above. Standard errors: of \(N\) from the standard error of the slope, and of \(E_\mathrm{fb}\) by the delta method from the variances and covariance of \(a\) and \(b\). Constants are the CODATA 2018 values (NIST): \(e = 1.602176634 \times 10^{-19}\) C and \(k = 1.380649 \times 10^{-23}\) J/K (exact), \(\varepsilon_0 = 8.8541878128 \times 10^{-12}\) F/m; \(kT/e = 25.693\) mV at 25 °C.

**The linear region.** Near \(E_\mathrm{fb}\) the depletion approximation fails and the plot bends; at high bias, surface states, a Helmholtz layer in series or the thickness of a thin film bend it too. Automatically, the analyzer takes the longest run of consecutive points (at least five, and a quarter of the data) in which a quadratic term does not improve the straight line significantly (F test, P ≥ 0.01), the rule of the LabCanvas Graph app’s Mott–Schottky analysis, so both give the same numbers. You can type the range instead.

**Frequency.** The capacitance of a real electrode is usually measured at several frequencies (for example 0.5, 1 and 2 kHz). If the space-charge capacitance is what you measure, the lines meet the axis at the same potential, though the slopes may differ; when E_fb moves with the frequency, the result is uncertain and the frequency should be reported. The analyzer fits every frequency and lists them side by side.

**RHE scale.** E(RHE) = E + E°(ref) + (ln 10·RT/F)·pH, with the reference electrodes and values of the [RHE converter](https://www.labcanvas.com/tools/rhe-calculator). The slope of 1/C² does not change; only the potentials shift.

## Worked example: an n-type film measured at three frequencies

The built-in example is synthetic, not a measurement: an n-type film with ε = 86 (the rutile value of Parker 1961, perpendicular to the c axis), N_D = 2 × 10¹⁹ cm⁻³ and E_fb = −0.950 V vs Ag/AgCl (saturated KCl), measured at 0.5, 1 and 2 kHz in an electrolyte of pH 14 at 25 °C, from −1.100 to −0.050 V in 25 mV steps. To make it realistic, the curve is rounded near E_fb, a 100 µF/cm² Helmholtz layer is in series, the capacitance falls slightly with frequency (C ∝ f^−0.03), and there is 0.4 % noise. The capacitance is per cm², so no area is needed.

- **Convert to RHE.** \(E(\mathrm{RHE}) = E + 0.199\) \({}+ 0.05916 \times 14\) \({}= E + 1.0272\ \mathrm{V}\).
- **Take 1/C².** At −0.500 V vs Ag/AgCl and 1 kHz, C = 5.0511 µF/cm², so \(1/C^2 = 1/(5.0511 \times 10^{-6})^2\) \({}= 3.919 \times 10^{10}\ \mathrm{cm^4\,F^{-2}}\).
- **Fit the straight part.** At 1 kHz the automatic region runs from 0.077 to 0.977 V vs RHE (37 points): slope \(b = (8.525 \pm 0.036) \times 10^{10}\) cm⁴ F⁻² V⁻¹, intercept \(a = -6.376 \times 10^{9}\) cm⁴ F⁻², R² = 0.99936.
- **Flat-band potential.** \(E_0 = -a/b = 0.0748\ \mathrm{V}\); the slope is positive, so n-type, and \(E_\mathrm{fb} = 0.0748 - 0.0257\) \({}= \mathbf{0.0491 \pm 0.0022\ V}\) **vs RHE** (−0.978 V vs Ag/AgCl).
- **Donor density.** \(N_\mathrm{D} = 2/(e\,\varepsilon\,\varepsilon_0\,b)\) \({}= 2/(1.6022 \times 10^{-19}\) \({}\times 86\) \({}\times 8.8542 \times 10^{-14}\ \mathrm{F/cm}\) \({}\times 8.525 \times 10^{10})\) \({}= \mathbf{1.92 \times 10^{19}\ cm^{-3}}\).

| Frequency | E_fb (V vs RHE) | N_D (cm⁻³) | R² |
| --- | --- | --- | --- |
| 500 Hz | 0.0494 | 1.99 × 10¹⁹ | 0.99923 |
| 1 kHz | 0.0491 | 1.92 × 10¹⁹ | 0.99936 |
| 2 kHz | 0.0506 | 1.84 × 10¹⁹ | 0.99931 |

The three lines meet the axis within 1.5 mV of each other while the slopes differ by 8 %: the dispersion changes N_D, not E_fb. The fitted E_fb is 28 mV below the true 0.077 V vs RHE, because the Helmholtz layer in series and the rounding near E_fb both bend 1/C². That is typical: a Mott–Schottky flat-band potential carries an uncertainty of some tens of millivolts beyond its standard error, so state the frequency, the region fitted and ε with the result.


## Relative permittivity ε of common semiconductors

N is inversely proportional to ε, so the value you use matters as much as the slope. These are static values of single crystals near room temperature, each from the paper cited; films, nanostructures and porous or doped oxides can differ a lot, and for many oxides used as photoelectrodes the published values spread widely. Use a value measured for your material if you can, and cite it.

| Material | ε | Note | Source |
| --- | --- | --- | --- |
| Si | 11.7 | 11.7 ± 0.2 at 1 MHz | Dunlap & Watters 1953 |
| GaAs | 13.09 | 12.35 × (1 + 2.01 × 10⁻⁴ K⁻¹ × 298.15 K) | Strzalkowski et al. 1976 |
| CdTe | 11.01 | 10.31 × (1 + 2.27 × 10⁻⁴ K⁻¹ × 298.15 K) | Strzalkowski et al. 1976 |
| ZnSe | 9.25 | 8.80 × (1 + 1.71 × 10⁻⁴ K⁻¹ × 298.15 K) | Strzalkowski et al. 1976 |
| TiO₂, rutile ⊥ c | 86 | a direction, 300 K | Parker 1961 |
| TiO₂, rutile ∥ c | 170 | c direction, 300 K | Parker 1961 |

Strzalkowski et al. give ε extrapolated to 0 K and a linear temperature coefficient λ (valid from 100 to 300 K); the values above are \(\varepsilon(0)\,(1 + \lambda T)\) at 298.15 K.

## Common Mott–Schottky mistakes

- **Capacitance of the whole electrode used as if per cm².** N scales with 1/A²: a 0.2 cm² electrode read as 1 cm² gives N 25 times too high. Enter the area, or the capacitance per cm².
- **Forgetting kT/e.** The x-intercept is E_fb + kT/e for n-type (E_fb − kT/e for p-type); at room temperature the difference is 25.7 mV.
- **Fitting the bend.** Points near E_fb and at high bias are not on the depletion line; including them moves the intercept.
- **One frequency, no check.** If E_fb changes with the frequency, the capacitance is not only the space charge’s (surface states, roughness, a porous film); report the frequency or the spread.
- **Mixing potential scales.** Convert to RHE (or state the reference) before comparing E_fb with band positions or other papers.

## References

- Gelderman K, Lee L, Donne SW. Flat-band potential of a semiconductor: using the Mott–Schottky equation. *J Chem Educ* 2007;84:685. [doi:10.1021/ed084p685](https://doi.org/10.1021/ed084p685)
- Bard AJ, Faulkner LR. *Electrochemical Methods: Fundamentals and Applications*, 2nd ed. Wiley; 2001, section 18.2 (semiconductor electrodes). ISBN 978-0-471-04372-0.
- Tiesinga E, Mohr PJ, Newell DB, Taylor BN. CODATA recommended values of the fundamental physical constants: 2018. *Rev Mod Phys* 2021;93:025010. [doi:10.1103/RevModPhys.93.025010](https://doi.org/10.1103/RevModPhys.93.025010) (NIST: [physics.nist.gov/cuu/Constants](https://physics.nist.gov/cuu/Constants/))
- Dunlap WC, Watters RL. Direct measurement of the dielectric constants of silicon and germanium. *Phys Rev* 1953;92:1396–1397. [doi:10.1103/PhysRev.92.1396](https://doi.org/10.1103/PhysRev.92.1396)
- Strzalkowski I, Joshi S, Crowell CR. Dielectric constant and its temperature dependence for GaAs, CdTe, and ZnSe. *Appl Phys Lett* 1976;28:350–352. [doi:10.1063/1.88755](https://doi.org/10.1063/1.88755)
- Parker RA. Static dielectric constant of rutile (TiO₂), 1.6–1060 °K. *Phys Rev* 1961;124:1719–1722. [doi:10.1103/PhysRev.124.1719](https://doi.org/10.1103/PhysRev.124.1719)


## Related calculators

- [RHE converter](https://www.labcanvas.com/tools/rhe-calculator): Potentials vs Ag/AgCl, SCE or Hg/HgO converted to the RHE scale, with iR correction and overpotential.
- [Tauc plot band gap calculator](https://www.labcanvas.com/tools/tauc-plot-band-gap-calculator): Optical band gap from a UV–vis or diffuse-reflectance spectrum by a Tauc plot, with its 95% CI.
- [Tafel slope calculator](https://www.labcanvas.com/tools/tafel-slope-calculator): Tafel slope in mV/dec and the exchange current density from a polarisation curve.
- [All 39 lab calculators](https://www.labcanvas.com/tools/lab-calculators)

## Use this calculator from code or an AI agent

This calculator also answers as JSON, computed by the same code as this page: no key, no account, CORS open. Send the parameters as a query string (numbers may carry units; lists comma-separated) or POST them as JSON to https://www.labcanvas.com/api/tools/mott-schottky-analyzer. An example, with the answer shortened to its first values:

```
GET https://www.labcanvas.com/api/tools/mott-schottky-analyzer?potential=-0.80%2C-0.75%2C-0.70%2C-0.65%2C-0.60%2C-0.55%2C-0.50%2C-0.45%2C-0.40%2C-0.35%2C-0.30&capacitance=9.907%2C8.366%2C7.375%2C6.669%2C6.133%2C5.709%2C5.362%2C5.072%2C4.824%2C4.609%2C4.421&permittivity=86&reference=agcl-sat&ph=14
```

```json
{
 "ok": true,
 "tool": "mott-schottky-analyzer",
 "inputs": {"potential":{"value":[-0.8,-0.75,-0.7,-0.65,-0.6,-0.55,-0.5,-0.45,-0.4,-0.35,-0.3],"unit":"V"},"capacitance":{"value":[9.907,8.366,7.375,6.669,6.133,5.709,5.362,5.072,4.824,4.609,4.421]},"permittivity":{"value":86}},
 "result": {"flat_band_potential":{"label":"Flat-band potential vs RHE","value":0.07714541225,"unit":"V"},"flat_band_potential_se":{"label":"Standard error of E_fb","value":0.00003042399416,"unit":"V"}},
 "answer": "n-type; E_fb = 0.07715 ± 3 × 10^-5 V vs RHE; N_D = 2 × 10^19 cm⁻³ (ε = 86); line over 0.2272 to 0.7272 V (11 points, R² = 1).",
 "formula": "1/C² = a + b·E by least squares (C per cm²); E0 = −a/b; E_fb = E0 − kT/e; N = 2/(e·ε·ε0·|b|) (Gelderman et al. 2007, doi:10.1021/ed084p685); E(RHE) = E + 0.199 V + ln10·RT/F × pH",
 "page": "https://www.labcanvas.com/tools/mott-schottky-analyzer",
 "citation": "LabCanvas Mott–Schottky analyzer, https://www.labcanvas.com/tools/mott-schottky-analyzer"
}
```

Parameters:

- `potential` (number[], V, required): Potential of each point (V vs your reference, or vs RHE).
- `capacitance` (number[], required): Space-charge capacitance of each point (or 1/C²), in capacitance_unit.
- `capacitance_unit` (string, default uF/cm2: uF/cm2 | F/cm2 | nF/cm2 | mF/cm2 | uF | F | nF | mF | invC2cm | invC2): uF/cm2, F/cm2, nF/cm2, mF/cm2 (per cm²); uF, F, nF, mF (whole electrode: give area); invC2cm (1/C² in cm⁴/F²) or invC2 (1/C² in F⁻², whole electrode).
- `permittivity` (number, required): Relative permittivity ε of the semiconductor (Si 11.7, GaAs 13.09, rutile TiO₂ 86 ⊥c or 170 ∥c).
- `area` (number, cm²): Electrode area (cm²), for a capacitance of the whole electrode.
- `temperature` (number, C, default 25): Temperature (°C), for kT/e and the Nernst slope.
- `fit_from` (number, V): Start of the linear region (V, on the reported scale); with fit_to. Default: found automatically.
- `fit_to` (number, V): End of the linear region (V, on the reported scale).
- `reference` (string, default none: none | agcl-sat | agcl-3m | agcl-4m | sce | hgo-1m | hgo-01 | hgo-naoh | she): Convert to RHE from this reference electrode (agcl-sat 0.199 V, sce 0.244, hgo-1m 0.098…); none keeps the measured scale.
- `ph` (number): pH of the electrolyte, for the RHE conversion.

All calculators: https://www.labcanvas.com/api/tools · OpenAPI 3.1: https://www.labcanvas.com/api/tools/openapi.json · MCP tool: `calc_mott_schottky_analyzer` (LabCanvas MCP server).

## Questions

### How do you calculate the flat-band potential from a Mott–Schottky plot?

Plot 1/C² (C per unit area) against the potential, fit a straight line to the linear part and find where it meets the potential axis, E₀ = −intercept/slope. For an n-type semiconductor (positive slope) the flat-band potential is E₀ − kT/e; for p-type (negative slope) it is E₀ + kT/e. kT/e is 25.7 mV at 25 °C.

### How do I calculate the donor density from the Mott–Schottky slope?

N_D = 2/(e·ε·ε₀·slope), with the slope of 1/C² against E in cm⁴ F⁻² V⁻¹, ε the relative permittivity, ε₀ = 8.854 × 10⁻¹⁴ F/cm and e = 1.602 × 10⁻¹⁹ C; N_D comes out in cm⁻³. If C is the capacitance of the whole electrode, divide also by A² (A in cm²). A slope of 8.5 × 10¹⁰ cm⁴ F⁻² V⁻¹ with ε = 86 gives 1.9 × 10¹⁹ cm⁻³.

### Does a positive or negative slope mean n-type or p-type?

A positive slope of 1/C² against potential means n-type (donors): anodic bias deepens the depletion layer. A negative slope means p-type (acceptors). The analyzer reads the type from the sign and reports N_D or N_A.

### Which frequency should I use for Mott–Schottky?

Measure at several frequencies in the range where the capacitance is that of the space charge, often around 0.5–10 kHz, and check that the flat-band potential does not depend on the frequency. Paste them all with a frequency column: the analyzer fits each one and compares them.

### What dielectric constant should I use?

The static relative permittivity of your semiconductor, ideally measured for the same kind of material. The table on this page gives referenced single-crystal values (Si 11.7, GaAs 13.1, rutile TiO₂ 86 or 170); thin films and nanostructures can differ, so state the value and its source with your result.

### Why is my Mott–Schottky plot not linear?

Near the flat-band potential the depletion approximation fails, and at high bias surface states, a Helmholtz layer in series, deep depletion or a thin film fully depleted bend the plot. A rough or porous electrode also gives frequency-dependent capacitance. Fit only the straight part and report the range.

### How do I convert the flat-band potential to the RHE scale?

E(RHE) = E(ref) + E°(ref) + 0.0592 V × pH at 25 °C: for Ag/AgCl in saturated KCl (0.199 V) at pH 14, add 1.027 V. Choose the reference and the pH in step 4, or use the RHE converter.

### Can I use the capacitance from an impedance fit?

Yes: paste the space-charge capacitance from your equivalent-circuit fit against potential. If you only have the imaginary impedance at one frequency, paste Z″ with the frequency and the analyzer takes C = 1/(2πf|Z″|), which assumes a simple series RC.