# Photocatalytic degradation kinetics: rate constant k, half-life and % degradation

> Rate constant k from ln(C0/C) vs time (pseudo-first-order), half-life ln2/k and % degradation, with the dark adsorption step and C0 at light-on. Free.

URL: https://www.labcanvas.com/tools/photocatalytic-degradation-kinetics

For photocatalytic degradation of a dye or pollutant, plot ln(C0/C) against irradiation time: for pseudo-first-order kinetics the points fall on a straight line whose slope is the apparent rate constant k_app, the half-life is ln 2/k_app, and the degradation is (1 − C/C0) × 100 %. C0 is the concentration when the light is switched on, after the dark adsorption–desorption step, not the concentration you started with. Paste time and concentration (or absorbance, proportional to concentration by Beer–Lambert) and the calculator finds C0 at light-on, fits the line, and gives k_app and t½ with 95 % confidence intervals, the removal in the dark and under light, and a second-order fit for comparison.

## Quick answer

- **What it does:** Fits the pseudo-first-order plot ln(C0/C) against time from light-on and gives the apparent rate constant, the half-life and the percentage degraded, keeping the dark adsorption step apart.
- **Formula:** ln(C0/C) = k_app·t;  t½ = ln 2 / k_app;  degradation = (1 − C/C0) × 100 %;  second order: C0/C = 1 + k2·C0·t
- **Example:** A 10 mg/L dye falls to 8.8 mg/L in 30 min in the dark (12.0 % adsorbed), then to 0.535 mg/L after 120 min of light: ln(C0/C) against t gives k_app = 0.02313 ± 0.00026 min⁻¹ (R² = 0.9991), t½ = 30.0 min (95 % CI 29.2–30.8 min) and 93.9 % photocatalytic degradation.

Free, in the browser, no account needed. Updated 2026-11-23.

## Features

- Pseudo-first-order plot ln(C₀/C) against irradiation time, with k_app ± SE, its 95 % confidence interval and R²
- Half-life t½ = ln 2/k_app with its 95 % confidence interval
- Dark adsorption step kept apart: C₀ is the sample at light-on; removal in the dark, under light and in all
- Concentration, absorbance (Beer–Lambert) or C/C₀ as input; time in s, min or h
- Line with an intercept (as SciPy linregress) or forced through the origin
- Second-order plot C₀/C against t for comparison, with k₂ when C₀ is a concentration
- C/C₀ decay curve and ln(C₀/C) plot as PNG, tables and methods to copy, CSV; opens in the Graph app

## How to use it

1. **Paste time and concentration**: One row per sample: the time and the concentration (or absorbance at the dye’s absorption maximum, or C/C₀), including the dark-phase samples and the one taken at light-on.
2. **Mark when the light went on**: Enter the time the lamp was switched on (0 when dark samples have negative times). Earlier samples are the dark adsorption step; C₀ is the sample at light-on.
3. **Read k and t½**: Read the apparent rate constant, the half-life and the percentage degraded, and check that ln(C₀/C) is a straight line.
4. **Report**: Copy the methods sentence and the table, download the plots (PNG) and the CSV, or open the plot in the Graph app.

## At a glance

| | |
| --- | --- |
| Model | Pseudo-first order: \(\ln(C_0/C) = k_\mathrm{app} t\) (least-squares line, with intercept or through the origin) |
| Gives | k_app ± SE and 95 % CI, t½ = ln 2/k_app with 95 % CI, R², % degradation, removal in the dark |
| C₀ | The sample at light-on (after the dark adsorption step); time counted from light-on |
| Input | Time with concentration, absorbance (Beer–Lambert) or C/C₀; s, min or h |
| Comparison | Second order: \(C_0/C = 1 + k_2 C_0 t\) |
| Output | C/C₀ and ln(C₀/C) plots (PNG), table and methods (copy), CSV; Graph app |

## How it works

$$\ln\frac{C_0}{C} = k_\mathrm{app}\,t \qquad t_{1/2} = \frac{\ln 2}{k_\mathrm{app}}$$

**Pseudo-first order.** The photocatalytic degradation of dyes and other organics on TiO₂ and similar catalysts is usually described by Langmuir–Hinshelwood kinetics, \(r = -\mathrm{d}C/\mathrm{d}t = k_r K C/(1 + K C)\), with \(k_r\) the reaction rate constant and \(K\) the adsorption constant; at low concentration (\(KC \ll 1\)) it reduces to first order, \(\ln(C_0/C) = k_r K t = k_\mathrm{app} t\) (Konstantinou & Albanis 2004; Houas et al. 2001). The calculator fits \(\ln(C_0/C)\) against the time from light-on by ordinary least squares, with an intercept (as SciPy’s `linregress`) or through the origin. The 95 % confidence interval of \(k_\mathrm{app}\) is the slope \(\pm\, t_{0.975,\,\mathrm{df}}\,\mathrm{SE}\), and that of \(t_{1/2}\) is \(\ln 2\) divided by its ends.

**Dark adsorption and C₀.** The suspension is usually stirred in the dark first, so the pollutant reaches adsorption–desorption equilibrium on the catalyst before irradiation (Houas et al. 2001). That drop is adsorption, not degradation: C₀ for the kinetics is the concentration at light-on, and time is counted from light-on. The calculator takes the sample at the light-on time as C₀ (or the last dark sample if there is none at that time) and reports the removal in the dark, \((1 - C_0/C_\mathrm{initial}) \times 100\), separately from the photocatalytic degradation, \((1 - C/C_0) \times 100\).

**Absorbance instead of concentration.** If you paste absorbance, the calculator uses \(A_0/A = C_0/C\), which holds when absorbance is proportional to concentration (the [Beer–Lambert law](https://www.labcanvas.com/tools/beer-lambert-law-calculator)): measure at the absorption maximum, in the linear range of a calibration, after removing the catalyst by centrifuging or filtering, and check that intermediates do not absorb at that wavelength. \(k_\mathrm{app}\) and \(t_{1/2}\) do not depend on the calibration; \(k_2\) of the second-order fit does, so give C₀ as a concentration for it.

**Second order, for comparison.** Some data follow second-order kinetics, \(1/C = 1/C_0 + k_2 t\); multiplied by \(C_0\), \(C_0/C = 1 + k_2 C_0 t\), so the slope of \(C_0/C\) against \(t\) is \(k_2 C_0\) and the half-life is \(1/(k_2 C_0)\). R² values of the two transformed plots are on different scales, so a higher R² is a hint, not a test.

**Langmuir–Hinshelwood constants.** \(k_\mathrm{app}\) depends on the initial concentration, the catalyst loading and the light intensity, so compare it only under the same conditions. To get \(k_r\) and \(K\), measure the initial rate \(r_0\) (or \(k_\mathrm{app}\)) at several \(C_0\) and fit \(1/r_0 = 1/k_r + 1/(k_r K C_0)\), a straight line in \(1/C_0\) (Konstantinou & Albanis 2004; see Kumar, Porkodi & Rocha 2008 on what the L–H constants mean).

## Worked example: a dye with 30 min of dark adsorption

The built-in example is synthetic, not a measurement: a 10 mg/L dye with catalyst, stirred in the dark for 30 min (to 8.8 mg/L), then irradiated for 120 min; the concentrations follow \(C = 8.8\,e^{-0.023 t}\) with each value scaled by 0.96–1.04 to mimic scatter.

| t (min) | C (mg/L) | Phase | ln(C₀/C) |
| --- | --- | --- | --- |
| −30 | 10.00 | dark |  |
| −15 | 9.05 | dark |  |
| 0 | 8.80 | light on: C₀ | 0 |
| 15 | 6.357 | light | 0.3252 |
| 30 | 4.348 | light | 0.7050 |
| 45 | 3.220 | light | 1.0054 |
| 60 | 2.147 | light | 1.4107 |
| 75 | 1.607 | light | 1.7004 |
| 90 | 1.088 | light | 2.0904 |
| 105 | 0.818 | light | 2.3756 |
| 120 | 0.535 | light | 2.8002 |

- **Dark step:** \(C_0 = 8.80\) mg/L at light-on, so \((1 - 8.80/10.00) \times 100\) \({}= 12.0\ \%\) was adsorbed before irradiation.
- **One point by hand:** at 60 min, \(\ln(8.80/2.147) = 1.4107\).
- **Fit the line** through the nine light points: slope \(k_\mathrm{app}\) \({}= 0.02313 \pm 0.00026\ \mathrm{min^{-1}}\) (95 % CI 0.02252–0.02375), intercept −0.0087, \(R^2 = 0.9991\). The data were made with 0.023 min⁻¹. Forced through the origin, \(k_\mathrm{app} = 0.02303\ \mathrm{min^{-1}}\).
- **Half-life:** \(t_{1/2} = 0.6931/0.02313 = 30.0\) min (95 % CI 29.2–30.8 min).
- **Degradation:** \((1 - 0.535/8.80) \times 100\) \({}= 93.9\ \%\) after 120 min of light; with the dark step, \(94.7\ \%\) of the dye was removed in all. Quoting 94.7 % as “photocatalytic degradation” would count the adsorption as reaction.
- **Second order, for comparison:** \(C_0/C\) against \(t\) curves upward (slope \(k_2 C_0 = 0.116\ \mathrm{min^{-1}}\), \(R^2 = 0.862\)), so first order describes these data better.

If the sample at light-on is missing, the last dark sample (9.05 mg/L at −15 min) is taken as C₀ and the fit uses the eight light samples: \(k_\mathrm{app} = 0.02319\ \mathrm{min^{-1}}\).


## References

- Konstantinou IK, Albanis TA. TiO₂-assisted photocatalytic degradation of azo dyes in aqueous solution: kinetic and mechanistic investigations. *Appl Catal B* 2004;49:1–14. [doi:10.1016/j.apcatb.2003.11.010](https://doi.org/10.1016/j.apcatb.2003.11.010)
- Houas A, Lachheb H, Ksibi M et al. Photocatalytic degradation pathway of methylene blue in water. *Appl Catal B* 2001;31:145–157. [doi:10.1016/S0926-3373(00)00276-9](https://doi.org/10.1016/S0926-3373(00)00276-9)
- Kumar KV, Porkodi K, Rocha F. Langmuir–Hinshelwood kinetics: a theoretical study. *Catal Commun* 2008;9:82–84. [doi:10.1016/j.catcom.2007.05.019](https://doi.org/10.1016/j.catcom.2007.05.019)


## Related calculators

- [Adsorption isotherm fitting](https://www.labcanvas.com/tools/adsorption-isotherm-fitting): Langmuir, Freundlich, Sips and Temkin isotherms fitted to Ce and qe by nonlinear least squares, with RL.
- [Tauc plot band gap calculator](https://www.labcanvas.com/tools/tauc-plot-band-gap-calculator): Optical band gap from a UV–vis or diffuse-reflectance spectrum by a Tauc plot, with its 95% CI.
- [Beer–Lambert law calculator](https://www.labcanvas.com/tools/beer-lambert-law-calculator): A = εlc for concentration, absorbance, ε or path length, %T to absorbance, and ε values with sources.
- [All 39 lab calculators](https://www.labcanvas.com/tools/lab-calculators)

## Use this calculator from code or an AI agent

This calculator also answers as JSON, computed by the same code as this page: no key, no account, CORS open. Send the parameters as a query string (numbers may carry units; lists comma-separated) or POST them as JSON to https://www.labcanvas.com/api/tools/photocatalytic-degradation-kinetics. An example, with the answer shortened to its first values:

```
GET https://www.labcanvas.com/api/tools/photocatalytic-degradation-kinetics?time=-30%2C-15%2C0%2C15%2C30%2C45%2C60%2C75%2C90%2C105%2C120&value=10%2C9.05%2C8.8%2C6.357%2C4.348%2C3.22%2C2.147%2C1.607%2C1.088%2C0.818%2C0.535
```

```json
{
 "ok": true,
 "tool": "photocatalytic-degradation-kinetics",
 "inputs": {"time":{"value":[-30,-15,0,15,30,45,60,75,90,105,120]},"value":{"value":[10,9.05,8.8,6.357,4.348,3.22,2.147,1.607,1.088,0.818,0.535]}},
 "result": {"k_app":{"label":"Apparent rate constant k_app","value":0.02313119051,"unit":"1/min"},"k_app_se":{"label":"SE of k_app","value":0.0002600441034,"unit":"1/min"}},
 "answer": "k_app = 0.02313 ± 0.00026 min⁻¹ (R² = 0.9991), t½ = 30 min; 93.9 % degraded under light, 12 % adsorbed in the dark.",
 "formula": "ln(C0/C) = k_app·t + b (least squares, t from light-on, C0 at light-on); t½ = ln 2/k_app; degradation = (1 − C/C0) × 100; second order C0/C = 1 + k2·C0·t",
 "page": "https://www.labcanvas.com/tools/photocatalytic-degradation-kinetics",
 "citation": "LabCanvas Photocatalytic degradation kinetics calculator, https://www.labcanvas.com/tools/photocatalytic-degradation-kinetics"
}
```

Parameters:

- `time` (number[], required): Sampling times (dark-phase samples before light_on).
- `value` (number[], required): Concentration (or absorbance, or C/C0) of each sample, in the same order.
- `light_on` (number, default 0): Time the light was switched on; earlier samples are the dark adsorption step.
- `origin` (boolean, default false): Force ln(C0/C) = k·t through the origin.
- `time_unit` (string, default min): Unit of time (answer text only).

All calculators: https://www.labcanvas.com/api/tools · OpenAPI 3.1: https://www.labcanvas.com/api/tools/openapi.json · MCP tool: `calc_photocatalytic_degradation_kinetics` (LabCanvas MCP server).

## Questions

### How do I calculate the rate constant of photocatalytic degradation?

Plot ln(C0/C) against irradiation time, with C0 the concentration when the light was switched on, and fit a straight line: its slope is the apparent pseudo-first-order rate constant k_app (min⁻¹ if time is in minutes). This calculator does the fit and gives k_app with its standard error and 95 % confidence interval.

### What is C0 in photocatalysis: the initial concentration or the one after the dark step?

For the kinetics, the concentration at light-on, after the adsorption–desorption equilibrium in the dark. The drop during the dark step is adsorption, not degradation. Report it separately as the removal in the dark.

### How do I calculate the percentage degradation?

Degradation (%) = (1 − C/C0) × 100, with C0 at light-on and C at the end of irradiation. With absorbance, use (1 − A/A0) × 100, which is the same when absorbance is proportional to concentration.

### Can I use absorbance instead of concentration?

Yes, if absorbance is proportional to concentration (Beer–Lambert): measure at the absorption maximum, within the linear range of a calibration, after removing the catalyst, and check that intermediates do not absorb there. ln(A0/A) then equals ln(C0/C), so k_app and the half-life are unchanged.

### How do I calculate the half-life?

For first-order kinetics t½ = ln 2 / k_app = 0.693 / k_app. With k_app = 0.0231 min⁻¹, t½ = 30.0 min. For second-order kinetics t½ = 1/(k2·C0), which depends on C0.

### Should the line go through the origin?

In theory ln(C0/C) = 0 at light-on, so a line through the origin is allowed; fitting an intercept as well shows whether the first minutes behave differently (an induction period, or fast initial adsorption). Report which you used; the two slopes are usually close.

### What is the Langmuir–Hinshelwood model?

A rate law for reactions on a surface: r = k_r·K·C/(1 + K·C), with k_r the rate constant and K the adsorption constant. At low concentration it reduces to pseudo-first order with k_app = k_r·K. To get k_r and K, measure initial rates at several C0 and plot 1/r0 against 1/C0.

### Why does my ln(C0/C) plot curve?

Common reasons: intermediates compete with the pollutant for the catalyst surface, the catalyst deactivates, the concentration is high enough that K·C is not small (Langmuir–Hinshelwood saturation), or absorbance is no longer proportional to concentration. Fit the early, straight part, and state the time range.