LabCanvas
Free account · save your work, full figure editorSign up free

Turnover frequency (TOF) and TON calculator

Turnover frequency is the number of molecules each active site converts per unit time: TOF = rate / number of active sites, in s⁻¹. In electrocatalysis the rate comes from the current, TOF = I·FE/(n·F·N), or per area TOF = j/(n·F·Γ) with Γ the sites per cm²: 10 mA/cm² of oxygen evolution (n = 4) on 1 nmol/cm² of sites is 25.9 s⁻¹. In heterogeneous catalysis TOF is the moles of product per second divided by the moles of active sites, often counted from the metal loading and its dispersion. The turnover number (TON) is the product per site over the whole run. A TOF is only as good as its site count, so state how the sites were counted.

What it does
Calculates the turnover frequency (s⁻¹ and h⁻¹) and the turnover number from a current or a reaction rate and a count of the active sites, for electrocatalysis and heterogeneous catalysis.
Formula
TOF=rNsitesTOF=I⋅FEnFNsites=j⋅FEnFΓTON=nproductNsites
Example
Oxygen evolution at 10 mA/cm² on 0.196 cm² (1.96 mA, n = 4) with 4.664 nmol of redox-active sites (a 0.45 mC redox peak) gives TOF = 1.96 × 10⁻³/(4 × 96485 × 4.664 × 10⁻⁹) = 1.089 s⁻¹; counting all 340.8 nmol of Ni in 0.05 mg of a 40 wt % Ni catalyst gives 0.0149 s⁻¹.

Last updated

FreeNo sign-upRuns in your browserLab calculators

Loading Turnover frequency (TOF) calculator…

At a glance

Turnover frequency (TOF) calculator at a glance
FormulaTOF = r/N; electrocatalysis TOF = I·FE/(n·F·N) = j·FE/(n·F·Γ); TON = n(product)/N
Sites fromMoles, Γ × area, redox charge Q/(zF), mass × wt % / M × dispersion, uptake × stoichiometry × mass
UnitsCurrent A–µA or per cm²; rate mol/s, mmol/h, µmol/min or per gram; TOF in s⁻¹, min⁻¹, h⁻¹
ConstantsF = e·N_A = 96 485.332 C/mol (CODATA 2018); CIAAW 2021 atomic weights
OutputTOF, product rate, sites, TON; CSV and a methods sentence
Runs inYour web browser; nothing is uploaded
PriceFree, no account needed

What it does

How to use the turnover frequency (TOF) calculator

  1. Choose the kind of catalysisElectrocatalysis (a current makes the product) or heterogeneous catalysis (a measured rate of product formation).
  2. Enter the rateElectrocatalysis: the current or current density with the electrode area, the product (for n) and the Faradaic efficiency. Heterogeneous: the rate of product formation, per gram if you like.
  3. Count the active sitesPick how: a redox-peak charge, the metal loading with its dispersion, a chemisorption uptake, a surface concentration, or the moles of sites.
  4. Read the TOFRead the TOF in s⁻¹ and h⁻¹, add a reaction time under More options for the TON, and copy the methods sentence with the site-counting method in it.

How it works

TOF=rNsites,TOF=I⋅FEnFNsites=j⋅FEnFΓ,TON=nproductNsites

Definition. The IUPAC Gold Book defines the turnover frequency as the number of molecules reacting per active site in unit time. Boudart (1995) calls it the turnover rate and counts the sites by titration with a chemisorbed molecule; Kozuch and Martin (2012) separate the turnover number, the product made per site over a run, from the turnover frequency, its rate. The calculator gives TOF in s⁻¹ (and min⁻¹, h⁻¹) and, with a reaction time and a constant rate, TON = TOF × t.

Electrocatalysis. A current I that makes a product with n electrons per molecule at Faradaic efficiency FE forms r=I⋅FE/(nF) moles per second, with F = 96 485.332 C/mol (CODATA 2018, exact as e·N_A). Divided by the moles of active sites this is the TOF; with a current density j and the sites per cm², Γ, it is j⋅FE/(nFΓ). Anantharaj et al. (2021) stress that the TOF should count only the current that makes the product, which is why FE is in the formula. When the sites are counted from the charge Q of a redox peak with z electrons per site, N=Q/(zF), and F cancels: TOF=I⋅FE⋅z/(nQ).

Heterogeneous catalysis. TOF = r/N with r in mol/s. A rate per gram is multiplied by the catalyst mass. Sites from the loading: N=m⋅w/M⋅D, the catalyst mass times the metal weight fraction over its molar mass, times the dispersion D (the fraction of metal atoms at the surface) or 1 to count every atom. Sites from a chemisorption uptake: N=u⋅s⋅m, the gas uptake per gram times the sites per adsorbed molecule (2 for dissociative H₂ on metals, usually 1 for CO) times the mass.

Which sites? The number of sites is the weak link. Counting every atom of the catalyst gives a lower bound of the TOF, counting only the surface atoms (dispersion) or the redox-active atoms gives a higher value, and the same data can give TOFs that differ by orders of magnitude. Report the counting method, and the potential or the temperature, pressure and conversion, with every TOF.

Worked examples: an electrocatalyst counted two ways, and a supported metal

1. Oxygen evolution, sites from a redox peak. A Ni-based film on a 0.196 cm² electrode carries 10 mA/cm² of oxygen evolution (n = 4, FE taken as 100 %). The Ni²⁺/Ni³⁺ peak before the onset holds Q = 0.45 mC, one electron per Ni (z = 1). The numbers are illustrative.

  1. Current: I=10 mA/cm2×0.196 cm2=1.96 mA.
  2. Product rate: r=I/(4F) =1.96×10−3/(4×96485.33) =5.078×10−9 molO2/s.
  3. Sites: N=Q/(zF)=0.45×10−3/96485.33 =4.664 nmol.
  4. TOF: 5.078×10−9/4.664×10−9 =1.089 s−1 (3920 h⁻¹); in one hour, TON = 3920.

2. The same film, every Ni atom counted. If the electrode carries 0.05 mg of a catalyst with 40 wt % Ni (58.6934 g/mol), it holds 0.05×10−3×0.40/58.6934 =340.8 nmol of Ni, and the TOF is 5.078×10−9/3.408×10−7=0.0149 s−1: 73 times lower, from the same measurement. Neither number is wrong; they answer different questions, and the paper must say which.

3. A supported metal in a flow reactor. 50 mg of a 1 wt % Pt/Al₂O₃ catalyst with a dispersion of 40 % (from H₂ chemisorption) makes 12 µmol/min of product. Sites: 0.050×0.01/195.084×0.40 =1.025 μmol. Rate: 12 μmol/min=2.0×10−7 mol/s. TOF = 2.0×10−7/1.025×10−6=0.195 s−1 (702 h⁻¹), and over 2 h, TON = 1405.

4. Straight from j and Γ. 10 mA/cm² of oxygen evolution on 1 nmol/cm² of sites: TOF=0.010/(4×96485.33×10−9) =25.9 s−1.

Ways to count the active sites

Site counts and what the TOF then means
MethodNWhat it counts
All atoms of the metal (loading)m·w/MEvery atom, bulk included: the lowest TOF, a lower bound
Loading × dispersionm·w/M·DSurface atoms, D from chemisorption or particle size
Chemisorption uptakeu·s·mSites that bind the probe gas (H₂, CO…), as Boudart counts them
Redox peak chargeQ/(zF)Electrochemically addressable redox centres (electrocatalysis)
Surface concentration ΓΓ·ASites per cm² from another measurement or a model of the surface

The ECSA calculator gives the electrochemically active area; multiplied by a site density per cm² it is another way to estimate N.

Common TOF mistakes

  • Not saying how the sites were counted. The TOF can change by orders of magnitude with the count; state the method with the number.
  • Using the total current when part of it makes something else. Multiply by the Faradaic efficiency of the product (the Faradaic efficiency calculator gives it).
  • The wrong n. Four electrons per O₂, two per H₂, two per CO, eight per CH₄ or NH₃ from nitrate.
  • Hours against seconds. 1 s⁻¹ is 3600 h⁻¹; say which.
  • TON from an initial TOF. TON = TOF × t only if the rate stays constant; otherwise divide the total product by the sites.

References

  1. IUPAC. “Turnover frequency”. Compendium of Chemical Terminology (the Gold Book). goldbook.iupac.org/terms/view/T06534, doi:10.1351/goldbook.T06534
  2. Boudart M. Turnover rates in heterogeneous catalysis. Chem Rev 1995;95:661–666. doi:10.1021/cr00035a009
  3. Kozuch S, Martin JML. “Turning over” definitions in catalytic cycles. ACS Catal 2012;2:2787–2794. doi:10.1021/cs3005264
  4. Anantharaj S, Karthik PE, Noda S. The significance of properly reporting turnover frequency in electrocatalysis research. Angew Chem Int Ed 2021;60:23051–23067. doi:10.1002/anie.202110352
  5. Anantharaj S, Ede SR, Karthick K, et al. Precision and correctness in the evaluation of electrocatalytic water splitting: revisiting activity parameters with a critical assessment. Energy Environ Sci 2018;11:744–771. doi:10.1039/C7EE03457A
  6. McCrory CCL, Jung S, Peters JC, Jaramillo TF. Benchmarking heterogeneous electrocatalysts for the oxygen evolution reaction. J Am Chem Soc 2013;135:16977–16987. doi:10.1021/ja407115p
  7. Tiesinga E, Mohr PJ, Newell DB, Taylor BN. CODATA recommended values of the fundamental physical constants: 2018. Rev Mod Phys 2021;93:025010. doi:10.1103/RevModPhys.93.025010
  • ECSA calculatorECSA and roughness factor from the double-layer capacitance (Cdl from CVs at several scan rates).
  • Faradaic efficiency calculatorFaradaic efficiency from GC ppm and gas flow, or from moles of product and the charge passed.
  • Tafel slope calculatorTafel slope in mV/dec and the exchange current density from a polarisation curve.
  • All 39 lab calculatorsSolutions, molecular biology, cell culture, assays, electrochemistry and materials, on one page.

Frequently asked questions

What is turnover frequency?

The number of molecules that each active site converts per unit time, usually in s⁻¹: the rate of the reaction divided by the number of active sites. The IUPAC Gold Book defines it as molecules reacting per active site in unit time.

How do you calculate TOF in electrocatalysis?

Divide the rate at which the current makes product by the moles of active sites: TOF = I·FE/(n·F·N), with I the current, FE the Faradaic efficiency, n the electrons per molecule and F = 96485 C/mol. Per area, TOF = j·FE/(n·F·Γ) with Γ the sites per cm². 10 mA/cm² of O₂ on 1 nmol/cm² of sites is 25.9 s⁻¹.

How do you calculate TOF from the metal dispersion?

Count the surface metal atoms as N = catalyst mass × metal weight fraction / molar mass × dispersion, then TOF = rate / N. 50 mg of 1 wt % Pt with 40 % dispersion holds 1.025 µmol of surface Pt; at 2.0 × 10⁻⁷ mol/s the TOF is 0.195 s⁻¹.

What is the difference between TOF and TON?

TON is the number of turnovers per site over the whole run (moles of product / moles of sites, dimensionless); TOF is the rate of turnovers (per second or per hour). For a constant rate, TON = TOF × time.

How do I count the active sites for TOF?

Choose a method and report it: every metal atom (a lower bound), the surface atoms from the dispersion or a chemisorption uptake, the redox-active atoms from the charge of a redox peak (N = Q/zF), or an ECSA times a site density. The same data give very different TOFs with different counts.

Should TOF include the Faradaic efficiency?

Yes. Only the part of the current that makes the product counts, so multiply the current by the Faradaic efficiency of that product. Anantharaj et al. (2021) stress normalising TOF by the Faradaic efficiency.

Is TOF given in s⁻¹ or h⁻¹?

Both are used: s⁻¹ in most electrocatalysis and surface science, h⁻¹ often in organic and homogeneous catalysis. 1 s⁻¹ = 60 min⁻¹ = 3600 h⁻¹; the calculator gives all three.

Why do published TOFs for similar catalysts differ so much?

Mostly because the sites are counted differently (all atoms, surface atoms, redox-active atoms) and because TOF depends on the potential, temperature, pressure and conversion. Compare TOFs only when these are stated and alike.

Make the whole figure in LabCanvas

Vector figure editor, slides, 3D models, protein structures and Prism-style graphs, in your browser.

Get started